Manrose Quiet Fan - 100mm - IPX5 Standard

The Manrose Quiet Fan X5 is the latest in domestic ventilation to incorporate a high extraction ra...

Best current price£51.99from B&Q

One Offer

1 offer from £51.99

View price history by clicking the chart icon.

B&QB&Q - 100mm Quiet Bathroom & Wc Fan Ipx5 Compliant Low Energy 25Db High ExtractionQf100Sx50P
Free delivery in 1–3 days
£51.99
Visit shop

Product Information

Full details

The Manrose Quiet Fan X5 is designed for homeowners seeking effective and whisper-quiet ventilation in bathrooms and toilets. Its key benefit is high extraction power (90m³/hr) combined with an exceptionally low noise level (25dB(A)), all while being IPX5 compliant for safe installation in Zone 1 areas without a low-voltage transformer. A potential consideration is its specific 100mm ducting requirement, which may necessitate adapter use for non-standard installations. This fan features a low-energy motor, a turning vane system for enhanced performance, and durable ABS construction.

All features

Model Part NumberQF100SX5OP
BrandManrose

Extended Product Information

FAQs

What does IPX5 compliance mean for installation?

IPX5 compliance means the fan is protected against water jets from any direction. This allows it to be safely installed in Zone 1 of a bathroom (an area within 0.6m of the shower basin) without needing a low-voltage transformer, simplifying installation and improving safety.

How quiet is the Manrose Quiet Fan X5?

The fan operates at a very low noise level of just 25dB(A) when measured at 3 meters, making it one of the quietest fans available for domestic use.

What is the extraction rate of this fan?

The fan has a high extraction rate of 90 cubic metres per hour (m³/hr), which is equivalent to 25 litres per second (l/s).

How much electricity does the fan consume?

It is an energy-efficient unit, consuming a maximum of 6 Watts.

What is the warranty period for this fan?

The fan features high-quality, long-life motors that are warranted for a minimum of 3 years or 30,000 hours of continuous use.

Can I use this fan with existing 4-inch ducting?

Yes, this fan is designed for 100mm (approximately 4-inch) ducting, which is a standard size for domestic ventilation systems.

Does the fan come with a power cord and plug?

The product information does not specify if a power cord and plug are included. Electrical connection typically requires hardwiring by a qualified electrician.

Troubleshooting

Fan does not operate

Check the power supply and ensure the circuit breaker is not tripped. Verify electrical connections are secure and correctly wired according to the installation manual. Ensure the fan is not obstructed.

Reduced airflow or poor performance

Check the ducting for any blockages, kinks, or obstructions. Ensure the fan grille is clean and free from dust or debris. Verify the turning vane system is intact.

Fan is making unusual noise

Ensure the fan is securely mounted and that no wires or debris are in contact with the fan blades. Check for obstructions within the ducting. If the noise persists, contact customer support.

Fan operates but is not extracting effectively

Confirm that the ducting is correctly connected and sealed. Ensure the duct run is as short and straight as possible. Check if the external vent or outlet is clear.

Pros and Cons

Pros

  • Extremely quiet operation minimizes noise disturbance.
  • IPX5 rating allows safe installation in wet bathroom zones.
  • High extraction rate ensures effective moisture and odour removal.
  • Energy-efficient with low power consumption.
  • Durable construction for long service life.

Cons

  • Requires 100mm ducting, potentially limiting compatibility with existing non-standard systems.
  • Installation in Zone 1 requires professional knowledge of electrical regulations.
  • Limited to ventilation tasks; does not include heating or humidity sensing features.

Setup, Compatibility & Care

Setup:

  1. Planning: Identify the desired mounting location. For optimal performance, position the fan on an inside wall or ceiling away from direct drafts.
  2. Ducting: Connect a 100mm diameter duct pipe to the fan's spigot. Ensure a secure and airtight connection.
  3. Electrical Connection: Wire the fan according to the manufacturer's instructions and local building regulations. Due to its IPX5 rating, it can be wired directly in Zone 1 without a low-voltage transformer, but professional installation is recommended.
  4. Mounting: Secure the fan unit to the wall or ceiling using appropriate fixings.

Compatibility:

  • Ducting: Compatible with standard 100mm (4-inch) flexible or rigid ducting.
  • Electrical: Requires a mains electrical supply compatible with its 6W motor. Check local voltage and wiring standards.
  • Location: Suitable for installation in bathrooms, shower rooms, and toilets, specifically compliant for Zone 1 (IPX5 rated).

Care:

  • Cleaning: Disconnect power before cleaning. Wipe the exterior with a soft, damp cloth. Avoid abrasive cleaners.
  • Grille: The fan grille can typically be removed for cleaning. Refer to the installation manual for specific instructions.
  • Motor: The motor is continuously rated and requires no user maintenance. Ensure ventilation openings are not obstructed.