Hep2O Gate Valve Hot / Cold 22mm - HX35/22W

Hep2O gate valve is a push-fit plumbing system providing optimum performance. It saves both time a...

Best current price£4.55from City Plumbing GB

All Offers

5 offers from £4.55 - £25.33

View price history by clicking the chart icon.

City Plumbing GBHep2o Gate Valve Hot/Cold 22Mm Hx35/22W
Free delivery in 1–3 days
£4.55
Visit shop
eBayWavin Hep2O 22mm x 22mm brass gate valve Hep20 push fit. HX35/22W.
£4.99 delivery
£10.99
Visit shop
B&QB&Q - Gate Valve Hot/cold 22mm Hx35/22W
Free delivery in 1–3 days
£25.33
Visit shop

Product Information

Full details

This guide is for anyone using the Hep2O Gate Valve (HX35/22W) in their plumbing projects. It's designed to streamline your plumbing work with its push-fit system and secure joint-recognition technology. Keep in mind that these valves are designed to be either fully open or fully closed; they are not intended for regulating flow.

All features

Model Part NumberHX35/22W
BrandHep2O

Extended Product Information

FAQs

What is the primary use of a Hep2O gate valve?

To allow temporary servicing of downstream equipment by shutting off water flow.

Can I use the Hep2O gate valve to regulate water flow?

No, it must only be used in the fully open or fully closed position.

What type of systems is the Hep2O gate valve compatible with?

Both hot and cold water applications, as well as central heating systems.

How do I install the Hep2O gate valve?

Ensure the pipe is cut cleanly and squarely. Insert the pipe into the valve until it reaches the stop. Confirm the connection is secure.

What should I do if the valve leaks?

Ensure the pipe is fully inserted and the connection is secure. Check for damage and re-install if needed.

Where can I find replacement parts?

Replacement parts can typically be found at plumbing supply stores or online retailers that carry Hep2O products.

Is the Hep2O gate valve suitable for potable water?

Yes, it is suitable for potable water applications when installed correctly.

Troubleshooting

Valve leaks after installation.

Ensure the pipe is fully inserted into the valve and that the connection is secure. Check for any damage to the pipe or valve. If necessary, demount and re-install.

Valve is difficult to open or close.

Check for any obstructions. Ensure the valve is not exposed to extreme temperatures. If the issue persists, the valve may need to be replaced.

Accidental demounting.

Confirm that the pipe has been fully inserted into the valve. Ensure that you hear a firm click when connecting.

Pros and Cons

Pros

  • Quick and easy installation with the push-fit design.
  • Reduces the risk of leaks with secure joint-recognition technology.
  • Versatile use in both hot and cold water systems.
  • Suitable for central heating applications.
  • Allows for temporary servicing of downstream equipment.

Cons

  • Must only be used in the fully open or fully closed position, not for flow regulation.
  • Specific to the Hep2O plumbing system.
  • Requires proper installation to ensure a secure seal.
  • Potential for issues if the pipe is not cut squarely.
  • May require specific tools for demounting (if needed).

Setup, Compatibility & Care

Setup

  1. Ensure the pipe is cut cleanly and squarely.
  2. Insert the pipe into the valve until it reaches the stop.
  3. Confirm the connection is secure. You should feel a firm click.

Compatibility

The Hep2O Gate Valve is designed for use with the Hep2O push-fit plumbing system. It is compatible with both hot and cold water applications and central heating systems.

Care

  • Regularly inspect the valve for leaks or damage.
  • Avoid using excessive force when operating the valve.
  • Do not overtighten if there is any threading involved.
  • Ensure that the valve is protected from freezing temperatures.

Similar items

Price History

DatePrice
Visit shop