Schneider Electric PratiKa Panel Socket - 63A - 400V - 5P - IP67 - 81283

Industrial panel mount socket with angled design featuring 3P+N+E configuration, rated for 63A at ...

Best current price£50.01from Tameson UK

All Offers

2 offers from £50.01 - £142.38

View price history by clicking the chart icon.

Tameson UKSchneider Electric Grey/Red Pratika 63A Ip67 Panel Socket 400V 5P - 81283
Free delivery in 1–3 days
£50.01
Visit shop
eBayIndustrial socket, square, 3p + N + E, 63A, 380...415 81283
£19.20 delivery
£142.38
Visit shop

Product Information

Full details

The Schneider Electric 81283 is an industrial panel mount socket designed for demanding environments. It offers a robust 63A, 400VAC rating with IP67 protection, making it ideal for secure and reliable power connections in harsh conditions. While its angled design aids cable management, users should ensure compatibility with existing panel cutouts and cable sizes.

All features

Model Part Number81283
BrandSchneider Electric

Extended Product Information

FAQs

What does IP67 mean for this socket?

IP67 means the socket is protected against dust ingress (first digit '6') and can withstand immersion in water up to 1 meter deep for 30 minutes (second digit '7'). This makes it highly suitable for harsh industrial and outdoor environments.

Can this socket be used for single-phase power?

No, this is a 3-phase socket with Neutral and Earth (3P+N+E). It is designed for three-phase power systems.

What is the recommended cable size for this socket?

The socket supports flexible or rigid cables ranging from 6mm² to 25mm².

How is the cable connected to the socket?

The socket uses a screwed terminal connection system. Cables are secured by tightening screws onto the stripped wire ends.

What is the purpose of the angled design?

The angled socket design, combined with the 6h clock position, helps to improve cable accessibility and manage cable routing, especially in installations with limited space behind the panel.

Is this socket suitable for outdoor use?

Yes, the IP67 rating provides excellent protection against dust and water, making it suitable for many outdoor applications provided it is installed correctly within a suitable enclosure or panel.

What certifications does this product have?

This product is certified with REACh and RoHS.

Troubleshooting

Socket not receiving power

Verify that the power source is active. Check all connections to the socket and upstream circuit breaker for tightness and correctness. Ensure the plug is fully inserted.

Water ingress detected

Immediately disconnect power. Inspect the housing and cable entries for damage. Ensure cable entries are correctly sized and sealed. Replace any damaged seals. If the internal components appear wet, professional inspection or replacement may be necessary.

Loose terminal connections

Disconnect power. Use a screwdriver to tighten the screws on the relevant terminals. Ensure the correct cable size is used and properly seated before tightening.

Overheating during operation

Disconnect power. Check if the connected load exceeds the 63A rating. Ensure terminals are tight and cable size is appropriate for the current. Verify adequate ventilation around the panel.

Pros and Cons

Pros

  • Exceptional IP67 dust and waterproof protection for harsh environments.
  • Robust IK08 impact resistance ensures physical durability.
  • Angled design improves cable accessibility and management.
  • Supports a wide range of cable sizes (6-25mm²).
  • Reliable 63A rating for significant industrial power loads.
  • Clear visual indicators for operational status.

Cons

  • Requires specific panel cutouts for mounting.
  • Angled design may not be suitable for all panel layouts.
  • Screwed terminal connections may require more time than lever-type terminals.
  • Limited to a single socket output.
  • Plastic housing, while durable, may be less resistant to certain chemicals than metal alternatives.

Setup, Compatibility & Care

Setup:

  1. Ensure the power source is disconnected before installation.
  2. Prepare the panel cutout according to the base plate dimensions (100x107mm).
  3. Secure the socket to the panel using the provided frame/mounting system.
  4. Open the appropriate cable entry (17-31mm range) and strip the cable.
  5. Connect the wires to the corresponding terminals (Phase 1, Phase 2, Phase 3, Neutral, Earth) using the screwed terminal system.
  6. Ensure all connections are tight and secure.
  7. Close the cable entry and ensure the seal is intact.

Compatibility:

  • Voltage: Compatible with 380-415V AC systems.
  • Frequency: Suitable for both 50Hz and 60Hz systems.
  • Cable Type: Supports flexible or rigid cables from 6mm² to 25mm².
  • Mounting: Designed for panel mounting; verify panel cutout dimensions.

Care:

  • Regularly inspect the socket for any signs of damage or wear.
  • Clean the exterior with a damp cloth. Avoid using abrasive cleaners or solvents.
  • Ensure cable entries remain sealed to maintain IP67 integrity.
  • Periodically check terminal tightness, especially after initial installation or significant temperature cycling.

Price History