Eaton Auxiliary Relay - DILE - 010223 DILER-40-G(24VDC)
This Eaton Moeller series DILER Contactor relay features a 24 V DC coil and screw terminals for DC...This Eaton Moeller series DILER Contactor relay features a 24 V DC coil and screw terminals for DC operation. It has 4 normally open (N/O) auxiliary contacts. The contact rating is 3 A at 400 V AC. The MPN is 010223 and DILER-40-G(24VDC). This relay is part of the xStart range and has a width of 45mm, depth of 54mm, and length of 58mm. It operates within a temperature range of -25°C to +40°C. The connection type for the auxiliary circuit is screw connection, and it can be mounted via DIN-rail or screw. It has 0 normally closed auxiliary contacts and 4 normally open auxiliary contacts.
This Eaton Moeller DILE series auxiliary relay is designed for industrial control systems requiring reliable DC operation. It is ideal for electricians and control panel builders who need to expand the contact capacity of existing control circuits. A key benefit is its four normally open (N/O) auxiliary contacts, offering flexibility in circuit design. However, users should note it is specifically for DC coil operation and comes with fixed N/O contacts, lacking normally closed (N/C) options.
All features
Series
DILE
Model Part Number
010223 DILER-40-G(24VDC)
Brand
Eaton
Extended Product Information
FAQs
What type of coil does this relay use?
This Eaton DILE series relay uses a 24 V DC coil.
How many auxiliary contacts does this relay have, and what type are they?
The relay has four normally open (N/O) auxiliary contacts. It does not have any normally closed (N/C) contacts.
What is the maximum current and voltage rating for the auxiliary contacts?
The auxiliary contacts are rated for 3 Amperes at 400 Volts AC.
Can this relay be mounted on a standard electrical panel?
Yes, it can be mounted using a standard 35mm DIN-rail or via screw mounting directly onto a panel.
What is the operating temperature range for this relay?
The relay is designed to operate reliably within a temperature range of -25°C to +40°C.
Is this relay suitable for AC control circuits?
The relay coil itself requires a 24 V DC supply. However, its auxiliary contacts can be used to switch AC loads up to 3 A at 400 V AC.
What are the physical dimensions of the relay?
The relay has a width of 45mm, a depth of 54mm, and a length of 58mm.
Troubleshooting
Relay coil does not energize
Verify that the 24 V DC power supply is connected correctly and is providing the correct voltage. Check wiring integrity to the coil terminals.
Auxiliary contacts do not switch
Ensure the relay coil is energized. Check that the contacts are wired correctly and that the load connected to the contacts does not exceed the 3 A at 400 V AC rating. Confirm that the contacts are not physically obstructed.
Intermittent operation
Check for loose wiring connections at the coil and auxiliary contacts. Ensure the ambient temperature is within the operational range (-25°C to +40°C). Inspect for any signs of physical damage or contamination.
Pros and Cons
Pros
Provides four N/O contacts for expanded control functionality.
Robust construction for industrial applications.
Versatile mounting options (DIN-rail or screw).
Compact size saves valuable panel space.
Designed for reliable DC coil operation.
Cons
Only provides normally open (N/O) contacts; no normally closed (N/C) contacts are available.
Fixed auxiliary contact configuration.
Contact rating may be insufficient for high-power switching.
Requires a 24 V DC power source for the coil.
Setup, Compatibility & Care
Setup:
Mounting: Secure the relay to a standard 35mm DIN-rail or use the provided screw mounting holes for direct panel attachment.
Wiring: Connect the 24 V DC coil to the appropriate power source. Wire the four N/O auxiliary contacts according to your control circuit diagram. Ensure all connections are made using the screw terminals and that wires are properly stripped and secured.
Compatibility:
This relay is designed for use with 24 V DC control circuits. Ensure your power supply voltage matches.
It is compatible with standard industrial control panels and wiring practices.
Care:
Keep the relay clean and free from dust and debris, which can affect performance and lifespan.
Periodically check wiring connections for tightness, especially in environments with vibration.
Avoid operating the relay outside its specified temperature range (-25°C to +40°C) or in excessively humid conditions.