Eaton NZMN2-A160 Circuit Breaker - 160A 3P 50kA

The Eaton Industries NZMN A is a 3-pole circuit breaker with a rated uninterrupted current (In = I...

Best current price£551.95from Tameson UK

All Offers

3 offers from £551.95 - £1,250.97

View price history by clicking the chart icon.

Tameson UKEaton Industries Eaton Nzmn2-A160 3P 160A Circuit Breaker - 259092
Free delivery in 1–3 days
£551.95
Visit shop
eBayBG2 NZMN2-A160 259092 3-Pole Power Switch 160A
£16.00 delivery
£934.15
Visit shop

Product Information

Full details

The Eaton NZMN2-A160 is a robust 3-pole circuit breaker designed for system and cable protection in industrial and commercial applications. It offers a high breaking capacity of 85,000 A at 400/415 V, ensuring reliable protection against overcurrents and short circuits up to 160A. While it provides excellent safety and meets stringent IEC standards, its fixed installation type requires professional setup.

All features

SeriesxEnergy
Model Part Number259092
BrandEaton

Extended Product Information

FAQs

What is the breaking capacity of the Eaton NZMN2-A160?

The breaking capacity (Icu) is 50 kA at 400/415 V 50 Hz, and the rated breaking capacity (Icn) is 85,000 A.

What is the rated current and voltage?

The rated uninterrupted current (In = Iu) is 160A, and the nominal voltage (Ue) is 690V.

How do I adjust the overload and short-circuit settings?

The overload protection setting (`Ir`) can be adjusted from 125A to 160A, and the un-delayed short circuit setting (`Im`) ranges from 960A to 1600A. Specific adjustment procedures should be followed from the product manual, typically involving turning adjustment dials.

What type of connection does this circuit breaker use?

This circuit breaker features screw connections for fixed installation.

Is this circuit breaker suitable for outdoor use?

The NZMN2-A160 has an IP20 rating, which means it is protected against solid objects larger than 12.5mm but has no protection against water. It should be installed in a suitable enclosure to protect it from environmental factors.

What does 'thermal magnetic tripping mechanism' mean?

It means the breaker uses two different mechanisms to detect overcurrents: a thermal element that detects sustained overloads (like a bimetallic strip) and a magnetic element that detects sudden, high-magnitude short circuits.

What are the dimensions of the breaker?

The dimensions are 105 mm in width and 149 mm in depth.

Troubleshooting

Circuit breaker trips immediately upon energization.

Check if the overload setting (`Ir`) is too low for the connected load or if there is a direct short circuit. Verify connections are secure and that the load is functioning correctly.

Circuit breaker does not trip during a fault.

Ensure the overload and short-circuit settings (`Ir` and `Im`) are correctly configured. Verify the fault current is sufficient to trigger the trip mechanism. If the issue persists, the device may be faulty and require replacement.

Device feels warm during normal operation.

Slight warmth can be normal due to current flow. However, if the breaker is excessively hot to the touch, check for loose terminal connections or if the continuous current exceeds the rated current (160A). Reduce the load or replace the breaker if necessary.

Difficulty adjusting trip settings.

Ensure the adjustment dials are being turned correctly as per the manufacturer's instructions. Do not force the dials. If they seem stuck, there might be an internal issue.

Pros and Cons

Pros

  • Excellent breaking capacity for robust fault protection.
  • Adjustable trip settings for tailored system protection.
  • Designed for reliability in demanding industrial environments.
  • Compact dimensions (105mm width, 149mm depth) for panel space efficiency.
  • Meets international safety certifications (IEC/EN 60947).

Cons

  • Fixed installation type requires professional installation and cannot be easily moved or replaced.
  • IP20 rating means it offers limited protection against dust and water ingress, requiring installation in an enclosure.
  • Overload and short circuit settings require careful calculation to avoid nuisance tripping or inadequate protection.

Setup, Compatibility & Care

Setup:

The Eaton NZMN2-A160 is a fixed installation device and requires professional installation by a qualified electrician. Ensure the power supply is completely disconnected before commencing any work.

  1. Mounting: Mount the circuit breaker securely onto a suitable DIN rail or mounting plate within an appropriate electrical enclosure.
  2. Wiring: Connect the incoming power conductors to the line-side terminals and outgoing load conductors to the load-side terminals using the provided screw connections. Ensure all connections are tight and properly insulated.
  3. Setting Adjustment: Before energizing, adjust the overload (`Ir`) and short-circuit (`Im`) trip settings according to the system's design specifications and cable ratings. Refer to the device's manual for detailed instructions on setting the thermal and magnetic trip units.

Compatibility:

  • Voltage: Rated for up to 690V, making it suitable for a wide range of industrial voltage systems.
  • Current: Designed for circuits with a rated current of up to 160A.
  • Standards: Compatible with systems designed to meet IEC/EN 60947 standards.

Care:

  • Environment: The device has an IP20 rating and should be installed in a clean, dry environment, preferably within an electrical enclosure to protect against dust and accidental contact.
  • Cleaning: Periodically inspect the device for dust accumulation. If cleaning is necessary, disconnect all power and use a dry or slightly damp cloth. Avoid using solvents or abrasive cleaners.
  • Inspection: Regular visual inspections for any signs of damage, discoloration, or loose connections are recommended. Ensure the adjustment dials for overload and short-circuit protection are still in their set positions.