Schneider Electric Multi 9 C60BP Circuit Breaker - 3P, 6A, Curve C

This low voltage circuit breaker (MCB) from Schneider Electric's Multi 9 series, specifically the ...

Best current price£54.19from Tameson UK

All Offers

4 offers from £54.19 - £107.38

View price history by clicking the chart icon.

Tameson UKSchneider Electric Circuit Breaker - M9f42210
Free delivery in 1–3 days
£54.19
Visit shop

Used Offers

2 offers from £26.69 - £63.00

View price history by clicking the chart icon.

eBaySchneider Electric M9F42206 Circuit Breaker... + Defective (281807)
£17.78 delivery
£26.69
Visit shop

Product Information

Full details

This Schneider Electric Multi 9 C60BP circuit breaker is designed for control panel builders and OEMs needing reliable 3-pole protection. Its key benefit is safeguarding electrical systems against short circuits and overloads with a 15 kA breaking capacity. A potential consideration is its specific application focus, making it ideal for professional installations rather than DIY projects.

All features

SeriesMulti 9
Model Part NumberM9F42306
BrandSchneider Electric

Extended Product Information

FAQs

What does '3P' mean for this circuit breaker?

'3P' stands for 3-pole, indicating that the breaker can simultaneously switch and protect three separate electrical conductors. This is commonly used for three-phase power or multiple single-phase circuits.

What is a 'Type C' tripping characteristic?

A Type C tripping characteristic is designed to handle moderate inrush currents, typically 5 to 10 times the nominal current, for a short duration. This makes it suitable for inductive loads like motors and transformers that experience higher currents upon startup.

What is the breaking capacity of this MCB?

The breaking capacity (Icu) is 15 kA at 440V AC. This means it can safely interrupt a short-circuit fault current of up to 15,000 Amperes at that voltage without being destroyed.

Can this breaker be used in residential applications?

While it provides protection, this model is specifically designed for control panel builders and OEMs. Residential applications might typically use different types of breakers optimized for those specific codes and requirements. Always consult local electrical codes and a qualified electrician.

How do I determine if a 6A rating is sufficient?

You need to calculate the total continuous current draw of the equipment or circuits the breaker will protect. Ensure this total does not exceed 80% of the breaker's 6A rating for continuous loads (NEC guidelines). Consult an electrical professional if unsure.

What is the operating temperature range?

The operating temperature range for this circuit breaker is -30°C to 70°C.

How many modules does this breaker occupy on a DIN rail?

This 3-pole breaker occupies 6 modules of 9mm width each on a standard 35mm DIN rail. This means it takes up a total width equivalent to 6 x 9mm = 54mm.

Troubleshooting

Breaker trips immediately upon energization

This typically indicates a short circuit. Disconnect all loads and re-energize with no load connected. If it still trips, inspect wiring for faults. If it holds with no load, the issue is with the connected load.

Breaker trips during normal operation

This suggests an overload condition. Verify that the connected load does not exceed the breaker's 6A rating. Check for excessive inrush current if the load involves motors or transformers.

Breaker will not reset after tripping

Ensure the fault condition that caused the trip has been cleared. If the breaker is mechanically damaged, it may need replacement.

Breaker feels warm during operation

Slight warmth can be normal due to current flow, but excessive heat indicates a potential issue. Check for loose connections or a load exceeding the breaker's continuous capacity. Ensure adequate ventilation around the breaker.

Pros and Cons

Pros

  • Robust protection against overloads and short circuits.
  • High breaking capacity ensures safety in demanding environments.
  • Durable construction for extended operational life.
  • Designed for easy and efficient DIN rail installation.
  • Type C curve is suitable for applications with moderate inrush currents.

Cons

  • Primarily intended for professional control panel builders and OEMs.
  • Specific 6A rating and Type C curve may not suit all electrical system requirements.
  • 3-pole configuration might be excessive for single-phase applications.
  • Requires standard DIN rail mounting infrastructure.

Setup, Compatibility & Care Instructions

Setup:

  1. Ensure the power to the circuit is completely de-energized.
  2. Mount the C60BP circuit breaker onto a standard 35mm DIN rail by snapping it into place.
  3. Connect the incoming power conductors to the designated terminals (typically top) and the outgoing load conductors to the lower terminals. For 3-pole units, ensure correct phase connections.
  4. Verify all connections are secure.
  5. Re-energize the circuit and test the breaker's functionality by engaging and disengaging the toggle.

Compatibility:

  • Compatible with standard 35mm DIN rail mounting systems.
  • Designed for use in AC electrical systems within its rated voltage (240V nominal, 480Y/277V UL rated) and frequency specifications.
  • Suitable for environments with ambient temperatures between -30°C to 70°C.

Care:

  • Keep the breaker clean and free from dust and debris. Use a dry cloth for cleaning; avoid solvents or liquids.
  • Periodically inspect connections for tightness and signs of corrosion.
  • The breaker is designed for long life with minimal maintenance. No user-serviceable parts are inside.