The Phoenix Contact 2908262 is a single-channel electronic circuit breaker designed for 24 V DC systems, offering reliable protection against overload and short circuits. It is ideal for industrial and automation applications where precise and flexible load protection is needed. A key benefit is its narrow 6 mm width, saving valuable control cabinet space. However, its electronic nature means it requires a stable DC power source and careful setting of nominal currents.
| Series | PTCB E1 |
|---|---|
| Model Part Number | 2908262 |
| Brand | Phoenix Contact |
The Phoenix Contact 2908262 has an adjustable nominal current range from 1A to 8A. You must set the device to the appropriate current level for your specific load.
No, this circuit breaker is specifically designed and rated for 24 V DC applications.
The device features an electronic adjustment mechanism. Refer to the product's specific manual or markings on the device for the exact procedure to set the desired nominal current.
IP20 means the device is protected against solid objects larger than 12.5 mm (like a finger) but offers no protection against water or moisture ingress.
The device is exceptionally narrow, measuring only 6.2 mm in width, 55.6 mm in depth, and 105.8 mm in height.
While it's designed for seamless integration with Phoenix Contact's CLIPLINE complete terminal block system, it can be wired into standard systems provided the electrical connections are made correctly and within the specified conductor size limits.
The device can operate within a temperature range of -30 °C to +60 °C.
Verify that the nominal current is set correctly for the load. Ensure the load is actually drawing current above the set threshold. Check that the input voltage is stable at 24 V DC.
The set nominal current might be too low for the load's startup current, or there may be a short circuit in the connected load. Check the load for faults or increase the set nominal current if appropriate.
Ensure the overload or short circuit condition has been cleared. Attempt to reset the device manually according to its operating instructions. If the issue persists, the device may require replacement.
Check all wire connections to the spring clamp terminals. Ensure conductors are properly inserted and secured. Re-terminate any loose wires.