Phoenix Contact Sensor/Actor Cable - 5m PUR Black - 1681897
This sensor/actuator cable from Phoenix Contact features a 4-position, PUR halogen-free design in ...This sensor/actuator cable from Phoenix Contact features a 4-position, PUR halogen-free design in black-gray (RAL 7021). It has a free cable end on one side and a right-angled M8 socket on the other, with a total cable length of 5 meters. The cable sheath is made of Polyurethane (PUR) and is black in color. It is suitable for a rated current of 4A and a rated voltage of 30V. The operating temperature range for the cable sheath after assembly is -40 to 80°C without vibration, and -25 to 90°C during assembly/handling. The multi-core cable has a cross-sectional area of 0.25 mm² (24 AWG). The connector housing on the M8 side is a female socket. This cable is shielded.
This Phoenix Contact 1681897 sensor/actuator cable is designed for industrial automation, offering a robust and reliable connection between sensors, actuators, and control systems. Its key benefit is the durable, halogen-free PUR cable sheath that ensures longevity in demanding environments, though its 5-meter length may require careful planning for specific installations. This shielded, 4-position cable features a free cable end on one side and a right-angled M8 socket on the other, providing flexibility in connecting various automation components.
All features
Colour
Black
Model Part Number
1681897
Brand
Phoenix Contact
Extended Product Information
FAQs
What does PUR halogen-free mean?
PUR stands for Polyurethane, a durable plastic material. Halogen-free means the cable sheath does not contain halogens (like chlorine or bromine), which makes it safer in case of fire as it emits less toxic smoke.
What is the maximum current and voltage this cable can handle?
This cable is rated for a maximum of 4A current and 30V voltage.
Can I cut the cable to a shorter length?
Yes, you can cut the cable to a shorter length. Ensure you properly terminate the cut end to prevent fraying and potential damage. The M8 end remains as is.
What type of connector is on the fixed end?
The fixed end features a right-angled M8 female socket.
Is this cable suitable for outdoor use?
While the PUR sheath offers good environmental resistance, it's primarily designed for industrial indoor applications. Prolonged direct outdoor exposure may degrade the material over time. Check specific environmental ratings if outdoor use is critical.
How do I identify the correct wires on the free cable end?
Typically, cables of this type have color-coded wires. Refer to the product datasheet or the device you are connecting to for the specific pinout and wire color assignments. Phoenix Contact products often include color-coding information.
What is the operating temperature range?
The operating temperature range for the cable sheath after assembly is -40 to 80°C without vibration, and -25 to 90°C during assembly/handling.
Troubleshooting
No signal transmission
Verify all connections at both the free cable end and the M8 socket. Check the pinout compatibility and ensure the connected devices are powered and functioning correctly. Test continuity of individual conductors using a multimeter.
Intermittent signal errors
Inspect the cable for physical damage. Ensure the M8 connector is securely seated. Check for potential sources of electromagnetic interference and ensure the cable's shielding is properly grounded if applicable.
M8 connector won't seat properly
Ensure the M8 socket on the device is clean and free of debris. Check for any damage to the threads or pins on either the cable or the device connector. Do not force the connection.
Cable sheath damaged
If the damage is minor and does not expose conductors, it may still function but replacement is recommended for reliability. If conductors are exposed, the cable must be replaced immediately to prevent short circuits and safety hazards.
Pros and Cons
Pros
Robust and durable construction suitable for industrial environments.
Halogen-free design for increased safety.
Shielded for reliable signal transmission.
Flexible connection options with a free cable end and angled M8 socket.
Good temperature resistance for reliable operation.
Cons
Fixed 5-meter length may not suit all applications.
M8 connector size limits the number of pins compared to larger connectors.
Right-angled connector can sometimes be bulky in extremely confined spaces.
PUR cable can be stiffer than PVC in very cold temperatures, affecting handling.
Setup, Compatibility & Care
Setup:
Free Cable End: Connect the wires from the free cable end to the appropriate terminals on your control system or junction box, ensuring correct polarity and secure connections. Use appropriate crimping or soldering techniques for a reliable connection.
M8 Socket: Simply plug the right-angled M8 socket into the corresponding M8 connector on your sensor or actuator.
Cable Routing: Route the cable to avoid sharp bends, excessive tension, or areas of high mechanical stress. Utilize cable glands and management systems where appropriate.
Compatibility:
Connectors: Designed for M8 standard connectors. Ensure your connected devices utilize compatible M8 sockets or plugs.
Control Systems: Compatible with PLCs and control systems that accept 4-position, 30V, 4A signals. Verify the pinout if connecting to non-standard devices.
Environment: Suitable for industrial environments with exposure to oils, chemicals, and moderate temperatures.
Care:
Cleaning: Clean the cable sheath and connectors with a soft, damp cloth. Avoid using harsh solvents or abrasive cleaners that could damage the PUR material.
Inspection: Periodically inspect the cable for any signs of damage, such as cuts, abrasions, or connector wear. Replace if damage is found to prevent failure.
Temperature Limits: Adhere to the specified operating temperature range (-40 to 80°C without vibration) to ensure longevity and performance. Avoid prolonged exposure outside this range.