Roofing Wall Breathable Membrane - 100g/m2 - 1.5m Wide - 3 Layer Permeable Insulation

Protect your roof structure with this breathable roofing membrane, designed to block wind-driven r...

Best current price£17.84from OnBuy.com

All Offers

10 offers from £17.84 - £68.24

View price history by clicking the chart icon.

OnBuy.com(1.5M X 5M) Roofing Wall Breathable Membrane 100G/M2 1.5M Wide 3 Layer Permeable Insulation 5063873006116
Free delivery in 1–3 days
£17.84
Visit shop

Product Information

Full details

The Vatec100 breathable roofing membrane is designed for builders and homeowners seeking superior protection for their roof structures. Its key benefit is blocking wind-driven rain while allowing moisture to escape, preventing condensation and extending roof life. A potential caveat is the need for proper installation to ensure optimal performance and weather resistance.

All features

Model Part NumberVatec100
BrandB2C

Extended Product Information

FAQs

What is the primary function of this breathable roofing membrane?

Its primary function is to protect the roof structure by blocking wind-driven rain while allowing moisture vapor to escape from within the building envelope, preventing condensation and improving air quality.

How is this membrane different from a standard roofing felt?

This membrane is breathable (vapor permeable), unlike many traditional roofing felts which are often impermeable. This breathability is key to preventing interstitial condensation and moisture buildup within the roof structure.

Can this membrane be used as a primary waterproofing layer?

No, this membrane is designed as an underlayment or wind barrier and is not intended as a primary waterproofing layer. It must be covered by a final weatherproofing material such as tiles, shingles, or metal sheeting.

What is the recommended overlap for this membrane?

Recommended overlap specifications are typically printed on the membrane itself or detailed in the manufacturer's technical data sheet. Generally, overlaps should be sufficient to ensure a continuous barrier, often ranging from 100mm to 150mm, and taped with compatible tape.

How long does the UV protection last?

The UV-stabilized surface provides protection for up to 6 weeks of direct sunlight exposure during the installation period. It is crucial to complete the final roof covering within this timeframe.

What type of fasteners should be used?

Corrosion-resistant fasteners such as stainless steel or galvanized staples or nails are recommended. The type and length should be suitable for the substrate and approved for construction use. Ensure fasteners are not over-driven.

Is this product suitable for use in extreme weather conditions?

While designed for robust protection, its suitability for extreme conditions depends on the overall roofing system design. Its 100g/m2 weight and 3-layer construction offer good performance, but specific regional building codes and climate requirements should always be consulted.

Troubleshooting

Wind-driven rain is still penetrating the roof structure.

Check for improperly sealed overlaps, damaged sections, or incorrect fastener placement. Ensure the membrane is installed with the correct side facing outwards and that all seams are properly taped and sealed according to manufacturer guidelines.

Excessive condensation observed inside the attic space.

Verify that the membrane's breathable properties are not compromised by inadequate ventilation of the roof structure. Ensure soffit and ridge vents are clear and functioning. The membrane allows vapor *out*, but proper air circulation is still required.

Membrane is showing signs of degradation before roof covering is installed.

Confirm that the roof covering was installed within the recommended 6-week UV exposure limit. If exposed for longer, the membrane may need replacement. Protect exposed areas with temporary coverings if installation is delayed.

Tearing during installation.

Handle the membrane carefully. Ensure substrate edges are smooth and free of sharp projections. Use appropriate fasteners and avoid over-driving them. For challenging areas, consider using a compatible sealing tape to reinforce potential stress points before fastening.

Pros and Cons

Pros

  • Provides excellent protection against wind-driven rain.
  • High vapor permeability prevents moisture buildup and condensation.
  • Durable 3-layer construction enhances tear resistance and lifespan.
  • Suitable for a wide range of roofing materials and wall insulation.
  • Easy to handle and install, saving time and labor.
  • Contributes to the longevity and efficiency of the building structure.

Cons

  • Requires proper installation techniques for maximum effectiveness.
  • UV protection is temporary (up to 6 weeks) and requires timely covering.
  • Not a primary waterproofing layer; must be used as an underlayment or insulation.
  • Specific weight (100g/m2) may not be suitable for all extreme climate conditions without additional measures.
  • Requires adequate ventilation of the roof space for optimal performance.

Setup, Compatibility & Care

Setup:

  1. Ensure the roof deck or wall substrate is clean, dry, and free of sharp objects.
  2. Unroll the membrane, ensuring the printed side (if any) faces outwards or as per manufacturer's specific instructions for air/water resistance.
  3. Overlap subsequent courses according to the recommended overlap guidelines (typically indicated on the product or in technical documentation) to ensure a continuous barrier.
  4. Secure the membrane using appropriate fasteners (e.g., cap nails or staples), ensuring they penetrate both the membrane and the substrate without causing undue damage.
  5. Use compatible tapes to seal overlaps and any necessary repairs.

Compatibility:

  • Roofing: Ideal as an underlayment for concrete tiles, clay tiles, metal roofing sheets, and asphalt shingles on pitched roofs.
  • Walls: Suitable for use as a windproof layer in timber frame construction.
  • Fasteners: Use corrosion-resistant fasteners approved for roofing and construction applications.
  • Adhesives/Tapes: Use only manufacturer-approved tapes and adhesives for sealing seams and penetrations to maintain the membrane's integrity.

Care:

  • The UV-stabilized surface provides temporary protection (up to 6 weeks) from direct sunlight. The roof or wall cladding should be installed within this timeframe to prevent premature degradation of the membrane.
  • Avoid excessive foot traffic or dragging sharp objects across the membrane during installation. Protective footwear is recommended.
  • Store the product in a cool, dry place away from direct sunlight and extreme temperatures before installation.

Similar items

Price History

DatePrice
Visit shop