Vimark V1298 Shower Ceiling Pull Switch - 45 Amp Double Pole

Vimark V1298 Shower Ceiling Pull Cord Switch 45 amp Double Pole Isolator Switch with neon indicato...

Best current price£6.00from eBay

All Offers

4 offers from £6.00 - £36.85

View price history by clicking the chart icon.

eBayDeta V1298 45A DP Ceiling Pull Cord c/w Neon
Free delivery in 1–3 days
£6.00
Visit shop
OnBuy.comVimark V1298 Shower Ceiling Pull Switch 45 Amp Double Pole Isolator Switch 5029163012984
Free delivery in 1–3 days
£12.00
Visit shop
B&QB&Q - V1298 Shower Ceiling Pull Isolator Switch Dp With Neon & Flag Indication 50 Amp
Free delivery in 1–3 days
£36.85
Visit shop

Product Information

Full details

The Vimark V1298 is a 45-amp double-pole isolator switch designed for electric shower circuits. It is ideal for homeowners or electricians needing a reliable and safe method to disconnect power to electric showers, offering a clear visual indicator and a mechanical off function. A potential consideration is its specific application for showers, meaning it may not be suitable for other high-current applications without electrical consultation.

All features

Model Part NumberV1298
BrandVimark

Extended Product Information

FAQs

What is a double-pole isolator switch?

A double-pole switch disconnects both the live and neutral conductors of an electrical circuit simultaneously, providing a higher level of safety compared to single-pole switches.

Can this switch be used for other appliances besides electric showers?

While rated for 45 amps, it is specifically designed for electric shower circuits. Its suitability for other high-current applications should be assessed by a qualified electrician based on specific load requirements and safety regulations.

How do I know if the power is off?

The neon indicator lamp on the switch will turn off when the switch is in the 'off' position and power is disconnected. Always verify with a voltage tester before performing any maintenance.

Is professional installation required?

Yes, due to the nature of electrical work, particularly with high-current appliances like electric showers, professional installation by a qualified electrician is strongly recommended and often required by regulations.

What is the purpose of the mechanical off function?

The mechanical off function ensures that once the switch is turned off, it will remain in the off position until it is manually reset, preventing accidental re-activation.

How long is the pull cord?

The pull cord length is typically standard for ceiling installations. Specific lengths can vary, and adjustments may be possible depending on the installation environment.

Troubleshooting

Neon indicator light does not turn on

Check that the main power supply is on and that the switch is in the 'on' position. Verify wiring connections to the neon indicator are secure.

Switch feels stiff or difficult to operate

Ensure there are no obstructions around the pull cord or switch mechanism. The internal components may require inspection by a qualified electrician.

Shower does not turn on when switch is activated

Verify that the main power is on at the breaker. Double-check all wiring connections from the switch to the shower unit. Consult a qualified electrician if issues persist.

Switch does not stay in the 'off' position

The mechanical off mechanism may be faulty. This unit should be inspected and potentially replaced by a qualified electrician.

Pros and Cons

Pros

  • Provides robust double-pole isolation for safety.
  • Neon indicator offers clear power status at a glance.
  • Easy to operate with a pull cord mechanism.
  • Designed specifically for demanding electric shower loads.
  • Mechanical off ensures the circuit remains disconnected.

Cons

  • Primarily designed for electric showers, limiting broader application.
  • Requires professional installation due to electrical nature.
  • Pull cord length may be fixed, potentially requiring adjustments for some installations.
  • Lack of advanced features like timers or remote control.

Setup, Compatibility & Care

Setup:

  1. Safety First: Ensure the main electrical supply to the shower circuit is completely turned OFF at the breaker or fuse box.
  2. Wiring: Connect the incoming live and neutral wires to the appropriate terminals on the switch, and connect the outgoing wires to the shower unit. Follow the specific wiring diagram provided with the product and local electrical codes.
  3. Mounting: Securely mount the switch to the ceiling using appropriate fixings, ensuring the pull cord is accessible but not a hazard.
  4. Testing: Once wired, restore power at the breaker and test the switch's functionality, including the neon indicator and the mechanical off mechanism.

Compatibility:

  • This switch is designed for electric shower circuits up to 45 amps.
  • It is a double-pole isolator, suitable for systems requiring this type of disconnection.
  • Professional installation is recommended to ensure compatibility with your specific electrical system.

Care:

  • Wipe clean with a slightly damp cloth. Avoid abrasive cleaners or solvents.
  • Periodically check the pull cord for wear and tear.
  • Ensure the area around the switch is kept free from excessive moisture or steam buildup.

Price History

DatePrice
Visit shop