Setup, Compatibility & Care
Setup: The MS30 connects via spring terminals. Ensure power is disconnected before wiring. Connect the live and neutral wires to the appropriate terminals and the switched live wire to the output terminal. Mount the sensor in a suitable location, ensuring its detection field is unobstructed.
Compatibility: This sensor is designed for use with LED lighting loads up to 400W. It is not suitable for dimmable lighting systems. It is rated IP20, meaning it is protected against solid objects larger than 12.5mm but offers no protection against water; therefore, it should only be installed in dry indoor locations.