Loops Telephone Line Extension Socket Wall Plate - 430A

Single BT Wall Extension Socket - IDC Terminals - 2/3C (with back box). This plate has a left hand...

Best current price£5.29from OnBuy.com

All Offers

3 offers from £5.29 - £6.89

View price history by clicking the chart icon.

OnBuy.comBt Telephone Line Extension Socket Wall Plate 2/3C Left Handed 430A 630A Plugs 5055538145650
Free delivery in 1–3 days
£5.29
Visit shop
B&Q - Bt Telephone Line Extension Socket Wall Plate 2/3C Left Handed 430A 630A Plugs
Free delivery in 1–3 days
£6.89
Visit shop

Product Information

Full details

This Loops Telephone Line Extension Socket Wall Plate (430A) is designed for users needing to extend an existing telephone line using IDC terminals. Its key benefit is providing a dedicated connection point for specific left-handed telephone plugs and curly cords, offering a reliable extension. A key caveat is that it cannot be used as a master socket and requires separate cabling and tools for installation.

All features

Model Part Number430A
BrandLoops

Extended Product Information

FAQs

Can I use this as my main phone socket?

No, this is strictly an extension socket and cannot be used as a master socket.

What type of plugs does this socket accept?

This socket is specifically designed for left-handed 430A or 630A plugs. It will not accept standard BT telephone plugs.

Do I need special tools to install this?

Yes, you will need an IDC tool to correctly terminate the wires into the IDC terminals. A BT crimper and BT connectors may also be required for older master sockets.

What is the difference between 430A and 630A plugs in relation to this socket?

This socket has 6 contact points and can be used with either 430A or 630A plugs, providing flexibility in compatibility.

Can I surface mount this socket anywhere?

Yes, it is designed for surface mounting and comes with a back box and fixing screws for easy installation on a wall.

What does ROHS compliant mean?

ROHS compliant means the product adheres to restrictions on the use of hazardous substances, ensuring it meets environmental standards.

How do I connect this to my existing phone line?

You need to run a telephone cable from your master socket or another extension socket to this socket's location. The cable is then terminated using an IDC tool into the terminals on the back of the plate.

Troubleshooting

No dial tone or poor line quality

Check all IDC connections are secure and correctly mapped (2-2, 3-3, 5-5). Ensure the extension cable is not damaged and is of appropriate type. Verify the master socket is functioning correctly. If using an older master socket, ensure the BT connector is properly crimped and seated.

Plug does not fit into the socket

Confirm you are using a compatible left-handed 430A or 630A plug. This socket is not designed for standard BT plugs.

Device connected via the extension socket does not work

Verify the extension cable is correctly connected at both ends. Test the device directly at the master socket to rule out device failure. Ensure the socket is wired as an extension and not attempting to be a master socket.

Faceplate does not fit securely onto the back box

Ensure the back box is mounted flush and securely to the wall. Check for any obstructions or damage to the back box or the rear of the faceplate.

Pros and Cons

Pros

  • Provides a dedicated and specific connection for left-handed telephone plugs.
  • Easy surface mounting with included back box and screws.
  • Uses IDC terminals for a secure and efficient cable connection.
  • ROHS compliant for environmental safety.

Cons

  • Cannot be used as a master telephone socket.
  • Requires separate purchase of cabling, IDC tool, and potentially BT adapters/crimpers.
  • The left-handed socket will not accept standard BT plugs.
  • Installation requires basic knowledge of telephone wiring.

Setup, Compatibility & Care Instructions

Setup:

  1. Choose Location: Select a suitable wall surface near the existing telephone line.
  2. Cable Run: Run a telephone cable (e.g., 2/3C) from your master socket or another extension socket to the new location.
  3. Mount Back Box: Secure the provided back box to the wall using the supplied fixing screws.
  4. Prepare Cable Ends: Using an IDC tool, strip and insert the wires from the extension cable into the IDC terminals on the back of the wall plate, ensuring correct wire-to-terminal mapping (2 to 2, 3 to 3, 5 to 5).
  5. Connect to Master Socket: For NTE5A sockets, connect to the IDC terminals on the removable front panel. For older sockets, crimp a BT connector onto the extension cable and plug it into the master socket.
  6. Attach Faceplate: Clip or screw the Loops wall plate onto the mounted back box.

Compatibility:

  • Compatible with telephone lines terminating in IDC connections.
  • Designed for left-handed 430A or 630A plugs only. It will not accept standard BT plugs.
  • Can be used with 630A or 430A plugs due to 6 contact points.
  • May require a BT splitter adapter if the master socket is still needed for a local phone.

Care:

  • Wipe clean with a dry or slightly damp cloth.
  • Avoid using abrasive cleaners or solvents.
  • Ensure connections remain secure and free from dust.