APC Metered-by-Outlet Rack PDU - AP8459WW

The APC Metered-by-Outlet Rack PDU provides individual outlet power metering to enable energy opti...

Best current price£909.04from PCHUB.UK

All Offers

4 offers from £909.04 - £1,184.35

View price history by clicking the chart icon.

PCHUB.UKApc Rack Pdu 2G. Metered-By-Outlet. Zerou. 16A. 100-240V. (21) C13 &Am
Free delivery in 1–3 days
£909.04
Visit shop
GamingKitApc Rack Pdu 2G. Metered-By-Outlet. Zerou. 16A. 100-240V. (21) C13 &Am
Free delivery in 1–3 days
£1,090.85
Visit shop
eBayApc Rack Pdu 2G Metered-By-Outlet Zerou 16A 100-240V 21 C13 & 3 C19. Pdu Types:
Free delivery in 1–3 days
£1,168.75
Visit shop

Product Information

Full details

The APC Metered-by-Outlet Rack PDU (AP8459WW) is designed for data center managers and IT professionals who require precise control and visibility over power consumption in high-density rack environments. By providing individual outlet metering, this PDU enables efficient load balancing and right-sizing of IT equipment to reduce operational costs. While it offers advanced remote management and security, users must ensure their existing infrastructure supports the 230V input requirements and 0U vertical mounting configuration.

All features

Model Part NumberAP8459WW
BrandA.P.C.

Extended Product Information

FAQs

What is the total power capacity of this PDU?

The AP8459WW supports a maximum total power draw of 3680 W.

Does this PDU support remote power cycling?

This model is 'Metered-by-Outlet,' meaning it provides power monitoring per outlet, but it does not support remote outlet switching (on/off).

Can I mount this horizontally?

No, this unit is designed specifically for vertical (0U) mounting within a rack.

What security protocols are supported for management?

The unit supports management via secure Web, SNMP, and Telnet interfaces.

Are the IEC receptacles locking?

Yes, this PDU features locking IEC receptacles to prevent cables from being accidentally unplugged.

What is the operating temperature range?

The operating temperature range is -5 to 45 °C.

Troubleshooting

Cannot access the web management interface

Verify that the Ethernet cable is securely connected and that the PDU has been assigned a valid IP address on your network.

LED indicator shows a circuit breaker trip

Reduce the total load on the PDU to below 3680 W, then reset the physical circuit breaker on the unit.

Sensor data is not appearing in the dashboard

Ensure the sensor is properly plugged into the designated temperature/humidity port and check for firmware updates on the PDU.

Pros and Cons

Pros

  • Granular per-outlet power data for accurate capacity planning
  • Space-efficient 0U design leaves rack space for critical IT equipment
  • Secure remote management via industry-standard protocols
  • Integrated sensor support for environmental monitoring
  • Locking receptacles prevent unintended power loss

Cons

  • Requires specific 230V AC power infrastructure
  • Vertical mounting may not fit all shallow-depth server cabinets
  • Advanced configuration requires familiarity with SNMP or CLI

Setup, Compatibility & Care

  1. Installation: This unit is designed for vertical 0U mounting within standard server racks. Ensure the rack has the necessary depth of 51 mm and sufficient height (1829 mm).
  2. Connection: Connect the PDU to a reliable 230V AC power source. Verify that your total load does not exceed 3680 VA.
  3. Configuration: Connect the device to your management network via the Ethernet port. Access the web interface using the default credentials to set up SNMP traps or security policies.
  4. Maintenance: Periodically check the locking mechanisms on the IEC cables to ensure they are fully seated. Monitor environmental logs for alerts from the optional sensors.
  5. Compliance: The unit is RoHS compliant and meets international safety standards including UL and VDE.