Push Fit Air Admittance Valve - Plumbright - AF110

The Air Admittance Valves are designed to allow the free entry of air into the sanitary pipework s...

Best current price£63.52from Travis Perkins

One Offer

1 offer from £63.52

View price history by clicking the chart icon.

Travis Perkins4TRADE AF110 Push Fit Air Admittance Valve Grey
£30.00 delivery
£63.52
Visit shop

Product Information

Full details

The Plumbright AF110 Push Fit Air Admittance Valve is designed for plumbers and homeowners seeking to maintain efficient sanitary pipework ventilation. Its primary benefit is preventing foul gasses from escaping into a building while allowing air entry, ensuring proper drainage function. A key consideration is its installation requirements, which must adhere to BS EN 12380 standards. This valve facilitates airflow, prevents odor escape, and can double as a secondary rodding point for blockages, operating effectively in temperatures from -20°C to +60°C without insulation.

All features

Model Part NumberAF110
BrandPlumbright

Extended Product Information

FAQs

What is an Air Admittance Valve (AAV)?

An Air Admittance Valve is a device that allows air to enter a plumbing drainage system, preventing sewer gases from escaping into the building while preventing siphonage of trap seals.

Can the Plumbright AF110 be installed horizontally?

The valve is designed for vertical installation to ensure proper function and prevent debris from entering the mechanism. Always refer to installation guidelines.

Does this valve require power or external ventilation?

No, the Plumbright AF110 is a passive device that operates automatically based on pressure changes within the drainage system.

What does 'A1 approved in accordance with BS EN 12380' mean?

This certification indicates that the product has met the stringent safety and performance standards set by the European standard for air admittance valves.

How do I know if my drainage system needs an AAV?

AAVs are typically required in plumbing systems where venting to the outside is difficult or not possible, especially in renovations or extensions, to ensure proper drainage and prevent odors.

What is the airflow capacity of the AF110?

The Plumbright AF110 has an airflow capacity of 43 L/s, ensuring efficient air admittance.

Can this valve be used to vent a new system?

AAVs are primarily used to supplement or replace traditional vent pipes where they cannot be installed. Always consult local building codes and a professional plumber for system design.

Troubleshooting

Drainage system gurgling or slow draining.

Check if the Air Admittance Valve is functioning correctly. Ensure it is not stuck closed or blocked. Inspect for any debris preventing it from opening.

Unpleasant odors detected in the building.

Verify that the Air Admittance Valve is properly sealed and functioning. If the valve is old or damaged, it may not be effectively preventing gas escape. Consider replacement.

Valve does not appear to open or close.

Ensure there are no obstructions around the valve mechanism. Test by creating a vacuum in the system; the valve should open to admit air.

Water seal in traps is siphoned out.

The valve may not be opening adequately to equalize pressure. Check for proper installation and ensure it is not being overwhelmed by excessive flow rates.

Pros and Cons

Pros

  • Effectively prevents the release of foul odors from drainage systems.
  • Designed for easy installation with push-fit connections.
  • Operates reliably across a wide temperature range without needing insulation.
  • Provides a dual function as a rodding point for maintenance.
  • Certified to BS EN 12380 standards for assured quality.

Cons

  • Requires adherence to specific installation standards (BS EN 12380).
  • May require professional installation to ensure compliance and proper function.
  • Primarily designed for air admittance, not for direct waste flow.

Setup, Compatibility & Care Instructions

Setup:

  1. Ensure the pipework is clean and free of debris before installation.
  2. Connect the Plumbright AF110 valve to the sanitary pipework using the push-fit mechanism. Ensure a secure and airtight connection.
  3. Install the valve in a vertical position, typically above the flood level of the lowest connected fixture, unless specifically approved for below flood level installation as per BS EN 12380 guidelines.
  4. Verify that the valve is accessible for future maintenance or use as a rodding point.

Compatibility:

  • This valve is designed for use in standard sanitary drainage systems.
  • It is compatible with pipework systems designed to BS EN 12380 standards.
  • Suitable for residential and commercial plumbing applications.

Care:

  • Regularly inspect the valve for any signs of damage or obstruction. Ensure the vent cap is clear of debris.
  • While the valve is designed to be maintenance-free, in areas prone to dust or debris, occasional cleaning of the exterior may be beneficial.
  • To clean, use a damp cloth. Do not use harsh chemicals or solvents, as they may damage the valve components.

Price History

DatePrice
Visit shop