Schneider Electric Auxiliary Contact - C60 - M9A26904

Best current price£29.75from Tameson UK
Best offers
Shopping.co.uk recommended and popular offers
Schneider Electric Schneider Multi9 M9a Of Auxiliary Contact 24-415Vac - M9a26904
Visit shop
Best current price£29.75from Tameson UK
Shopping.co.uk recommended and popular offers
Schneider Electric Schneider Multi9 M9a Of Auxiliary Contact 24-415Vac - M9a26904
Visit shop1 offer from £29.75
View price history by clicking the chart icon.
This Schneider Electric Auxiliary Contact (M9A26904) is designed for electrical professionals who need reliable remote position indication for compatible Multi9 series circuit breakers. Its key benefit is providing clear signalling to PLCs or monitoring systems, ensuring operational awareness. A potential caveat is its specific compatibility requirements with certain Schneider Electric circuit breaker series.
| Series | Multi9 |
|---|---|
| Model Part Number | M9A26904 |
| Brand | Schneider Electric |
Its primary function is to provide remote indication of the associated circuit breaker's status (e.g., tripped, closed, open) to control systems or monitoring equipment.
It is compatible with Schneider Electric's C60BP, C60SP, C60, and N40 series circuit breakers.
It features a clip-on mounting system for easy installation onto a standard DIN rail, alongside the compatible circuit breaker.
It offers one Changeover (C/O) contact, meaning it has one common terminal, one normally open (NO) terminal, and one normally closed (NC) terminal.
The contact current rating is 6A, and the contact voltage rating is 250V.
No, the auxiliary contact itself does not require external power. It operates based on the mechanical state of the associated circuit breaker and provides a signal output.
The operating temperature range for this auxiliary contact is from -25°C to +70°C.
Verify that the associated circuit breaker is in the expected state (e.g., tripped or closed). Ensure wiring to the auxiliary contact is secure and correctly connected to the signaling device (e.g., PLC). Check compatibility of the circuit breaker with the auxiliary contact.
Ensure the auxiliary contact is properly clipped onto the circuit breaker and secured to the DIN rail. Re-seat the unit if necessary.
Confirm the wiring configuration matches the desired C/O (Changeover) function. Double-check that the auxiliary contact is correctly paired with the circuit breaker it is intended to monitor.
Setup:
Compatibility:
This auxiliary contact is designed for use with the following Schneider Electric circuit breaker series:
Verify that your circuit breaker is one of these compatible models before installation.
Care: