Setup, Compatibility & Care
Setup:
This switched fused spur is designed to replace a standard 13A fused connection unit or be installed as a new connection point. It requires wiring into the mains electrical supply by a qualified electrician. Ensure the power is switched off at the main consumer unit before commencing any installation work.
- Prepare the Back Box: Ensure a standard single-gang electrical back box is installed and suitable for surface or flush mounting as required.
- Connect Wiring: Connect the incoming live, neutral, and earth wires to the appropriate terminals on the back of the spur. Ensure all connections are secure.
- Install Fuse: Insert the correct rating fuse (e.g., 5A or 13A) for the appliance being connected into the fuse holder.
- Mount the Spur: Secure the Varilight spur to the back box using the provided screws.
- Attach Fascia: Clip the decorative brushed copper fascia onto the unit.
- Restore Power: Once installation is complete and verified by a qualified electrician, restore power at the consumer unit.
Compatibility:
- Compatible with standard UK single-gang back boxes.
- Suitable for connecting appliances requiring a 13A fused connection.
- Designed for use with 230V AC mains electricity.
Care:
To maintain the aesthetic appeal of the brushed copper finish:
- Dust regularly with a soft, dry cloth.
- For stubborn marks, use a slightly damp cloth with water. Dry immediately afterwards.
- Avoid using abrasive cleaners, solvents, or metal polish, as these can damage the finish.