This flexible condensate pipe kit from McAlpine is designed for the installation of condensing boi...This flexible condensate pipe kit from McAlpine is designed for the installation of condensing boilers. It eliminates the need for traditional rigid discharge pipe and fittings, offering complete flexibility to the discharge point. The kit includes a 3m length of 25mm flexible pipe, 6 x 25mm pipe clips, 2 x straight connectors with universal connection suitable for 19/23mm rigid pipe and 25mm flexible pipe, and a 1 x 1 1/2" plain tail ABS solvent weld reducer to 19/23mm rigid pipe and 25mm flexible pipe. These fittings allow for easy connection to sanitary pipework. In freezing conditions, the pipe can be disconnected for the discharge to be redirected into a receptacle. This kit is particularly useful in installations where space is restricted and conforms to BS 6798:2009 and Building Regulations Approved Document H.
This guide is for homeowners and installers using the McAlpine Flexible Condensate Pipe Kit (CONFLEX-KIT1). It simplifies the installation of condensing boilers by providing a flexible solution for condensate discharge, especially in tight spaces. However, it's essential to ensure proper connection to prevent leaks.
All features
Model Part Number
CONFLEX-KIT1
Brand
McAlpine
Extended Product Information
FAQs
What is included in the kit?
The kit includes a 3m length of 25mm flexible pipe, 6 x 25mm pipe clips, 2 x straight connectors with universal connection, and a 1 x 1 1/2" plain tail ABS solvent weld reducer.
Can I use this kit with any condensing boiler?
The kit is compatible with most condensing boilers. However, always check the boiler's specifications to ensure compatibility with 25mm flexible pipe.
How do I connect the pipe to the sanitary pipework?
Use the provided connectors. They are designed to connect to both 19/23mm rigid pipe and 25mm flexible pipe.
What should I do if the pipe freezes?
Disconnect the pipe from the discharge point and redirect the discharge into a suitable receptacle until the weather improves.
What are the building regulations this kit conforms to?
The kit conforms to BS 6798:2009 and Building Regulations Approved Document H.
How do I maintain the pipe?
Regularly inspect the pipe for any damage, leaks, or blockages. Clean any debris to ensure proper drainage.
Where can I use this kit?
This kit is particularly useful in installations where space is restricted, such as small utility rooms or areas with many obstacles.
Troubleshooting
Leakage at connections
Ensure all connections are securely tightened and properly sealed. Check for any damage to the connectors or pipe.
Slow drainage
Check for any kinks or blockages in the pipe. Clear any debris that may be obstructing the flow.
Pipe sagging
Use the provided clips to secure the pipe at regular intervals, ensuring it is properly supported.
Pros and Cons
Pros
Flexible design allows for easier routing and installation.
The kit includes all necessary components for a standard installation.
Suitable for use in restricted spaces.
Easy connection to sanitary pipework.
Allows for temporary redirection of discharge in freezing conditions.
Compliant with relevant building regulations.
Cons
Requires careful installation to ensure leak-proof connections.
The 3m pipe length may not be sufficient for all installations.
May require additional components for non-standard setups.
The flexibility could potentially lead to sagging or kinking if not properly supported.
Setup, Compatibility & Care
Installation:
Connect the 25mm flexible pipe to the boiler condensate outlet.
Use the provided connectors to join the flexible pipe to the sanitary pipework.
Secure the pipe with the provided clips, ensuring it slopes downwards to allow for proper drainage.
Compatibility:
Compatible with most condensing boilers.
Suitable for use with 19/23mm rigid pipe and 25mm flexible pipe.
Ensure compatibility with your boiler's condensate outlet.
Care:
Inspect the pipe regularly for any signs of damage or leaks.
Clean any debris or blockages from the pipe to maintain proper drainage.
In freezing weather, consider redirecting the discharge into a receptacle to prevent ice buildup.