The Burkert Solenoid Valve 221753 is a 2/2-way, normally closed valve designed for efficient control of liquids and gases. It's ideal for applications requiring reliable on/off switching without a minimum pressure differential, such as in water treatment, heating systems, and compressed air applications. A key benefit is its ability to operate from 0 bar, ensuring consistent performance. However, it requires a separate electrical connector and is best suited for clean, neutral media.
| Model Part Number | 221753 |
|---|---|
| Brand | Burkert |
This valve is designed for clean, neutral liquids and gases. It is not suitable for abrasive particles, viscous fluids, or aggressive chemicals. Examples include water, air, and certain inert gases.
No, the DIN connector is not included with the valve and must be ordered separately.
The valve is semi-direct operating and can open from 0 bar (no differential pressure required). A minimum pressure difference of 0.1 bar is needed for it to completely open.
The valve is suitable for media temperatures ranging from -10 °C to a maximum of 80 °C (176 °F).
The Kv value indicates the flow rate of water in m³/h at a pressure drop of 1 bar. For your application, ensure the valve's Kv value (30 m³/h) is sufficient for the required flow, considering the specific fluid and pressure conditions.
Yes, the valve can be used in vacuum systems as it operates from 0 bar and is designed for robust sealing.
While not explicitly stated in the provided details, similar Burkert solenoid valves often have an IP65 rating when properly connected, indicating protection against dust and low-pressure water jets.
Check if the 230 V AC supply is correctly connected to the coil. Ensure the coil is properly seated. Verify that the media pressure is not exceeding the maximum operating limit or that there isn't an internal blockage.
Confirm that the electrical supply has been completely removed from the coil. Check for debris or foreign matter that might be preventing the valve from seating properly. Ensure the spring return mechanism is not obstructed.
Inspect and re-tighten pipe connections. Check the sealing surfaces of the valve body and mating components for damage. If the leak persists, the internal seals (NBR) may need replacement.
Check the inlet and outlet ports for blockages caused by sediment or foreign particles. Clean the valve's internal passages if necessary, ensuring the media is compatible. Verify that the Kv value is adequate for the application's flow requirements.
While the design minimizes this, ensure smooth electrical switching and proper system pressure. Check for any excessive vibration or turbulence in the fluid flow.
Setup:
Compatibility:
Care: