Setup, Compatibility & Care Instructions
Compatibility: The FilterLogic VFL-430 is compatible with Lincat FilterFlow FX Series boilers, including models such as EB3FX, EB4FX, EB6FX, EB6TFX, EB3FX/PB, and EB3FX/TT. Important: It is not compatible with models where the part number ends solely with 'F' (e.g., EB3F), which require the Lincat FC02 filter.
Setup:
- Ensure the boiler is switched off and unplugged from the power source.
- Locate the existing water filter housing.
- Carefully unscrew and remove the old filter cartridge.
- Insert the new FilterLogic VFL-430 cartridge, ensuring it is seated correctly.
- Reassemble the housing and ensure it is secure.
- Turn on the water supply and flush the system by running the boiler for several minutes, discarding the first batch of water.
Care:
- Replace the filter cartridge approximately every 6 months to maintain optimal performance and water quality.
- Regularly check the filter housing for any leaks after installation.
- Do not use the filter with microbiologically unsafe water or water of unknown quality without adequate disinfection.