Plumbright Condensate Soakaway Unit for Condensing Boilers - BSOAK
The Plumbright Condensate Soakaway enables the controlled release of condensate from boilers into ...The Plumbright Condensate Soakaway enables the controlled release of condensate from boilers into the ground. Where a suitable gravity drain point is unavailable, the Plumbright Soakaway unit should be used installed in conjunction with 10mm lime chippings to neutralise any acidity. This provides a more environmentally friendly system, which requires less maintenance, stopping any unwanted acidic residue seeping into the ground. Using the soakaway unit also provides less chance of the acidic condensate from being trapped in the system, ensuring a longer life of the central heating system. The Plumbright Soakaway Unit is compatible with the following pipe sizes: 22mm (3/4 inch), 32mm (1 1/4 inch), and 40mm (1 1/2 inch).
The Plumbright Condensate Soakaway Unit is designed for homeowners with condensing boilers who need a safe and environmentally friendly way to dispose of condensate. Its key benefit is neutralizing acidic condensate before it enters the ground, protecting your property and the environment. However, it requires proper installation with lime chippings for optimal performance.
All features
Model Part Number
BSOAK
Brand
Plumbright
Extended Product Information
FAQs
What is the purpose of the lime chippings?
The lime chippings neutralize the acidity of the condensate, preventing damage to the surrounding environment and your property.
How often should I replace the lime chippings?
The lime chippings typically need to be replaced every few years, depending on usage.
What pipe sizes are compatible with the unit?
The unit is compatible with 22mm (3/4 inch), 32mm (1 1/4 inch), and 40mm (1 1/2 inch) pipes.
Where should I install the Plumbright Condensate Soakaway Unit?
The unit should be installed in the ground.
What happens if the condensate is not neutralized?
Untreated condensate can damage the surrounding environment and potentially corrode pipes and other components of your central heating system.
Troubleshooting
Condensate not draining properly.
Check for any blockages in the pipe or the unit itself. Ensure the unit is installed correctly and that the lime chippings are not compacted.
Unpleasant odor near the unit.
This could indicate a problem with the neutralization process. Inspect the lime chippings and replace them if necessary.
Pros and Cons
Pros
Environmentally friendly condensate disposal.
Reduces the risk of corrosion in your central heating system.
Low-maintenance design.
Compatible with multiple pipe sizes.
Cons
Requires installation with lime chippings.
May require periodic inspection to ensure proper function.
Setup, Compatibility & Care
Installation: The Plumbright Condensate Soakaway Unit should be installed in the ground.
Lime Chippings: Ensure the unit is installed with 10mm lime chippings for effective neutralization.
Pipe Compatibility: The unit is compatible with 22mm (3/4 inch), 32mm (1 1/4 inch), and 40mm (1 1/2 inch) pipes.
Care: Periodic inspection of the unit is recommended. Check for any blockages or signs of damage. Replace the lime chippings as needed, typically every few years depending on usage.