Siemens SIMATIC PLC Communication Module - 6ES72411CH301XB0

This Siemens I/O communication module is specifically designed for use with the S7-1200 series, fa...

Best current price£109.43from Rapid Online - Rapid Electronics Ltd.

All Offers

5 offers from £109.43 - £282.21

View price history by clicking the chart icon.

Rapid Online - Rapid Electronics Ltd.Siemens 6ES7241-1CH30-1XB0 CB 1241 Communication Module S7-1200
Free delivery in 1–3 days
£109.43
Visit shop
Tameson UKSiemens Simatic Plc Communication Module - 6Es72411ch301xb0
Free delivery in 1–3 days
£129.71
Visit shop
eBaySiemens 6ES7241-1CH32-0XB0 CM 1241 Communication Module
Free delivery in 1–3 days
£181.83
Visit shop

Product Information

Full details

The Siemens 6ES7241-1CH30-1XB0 is a specialized communication board designed for industrial automation engineers and technicians working with the SIMATIC S7-1200 PLC series. It provides a robust solution for RS485 serial data exchange, enabling seamless integration of Freeport protocols into existing control architectures, though users should note it is strictly limited to S7-1200 compatibility.

All features

BrandSiemens

Extended Product Information

FAQs

Is this module compatible with S7-1500 series?

No, the 6ES7241-1CH30-1XB0 is exclusively designed for the SIMATIC S7-1200 PLC series.

Does this module require an external power supply?

No, it is powered directly via the backplane connection of the S7-1200 CPU.

What is the primary use of the Freeport protocol?

Freeport allows you to communicate with devices that do not support standard protocols like Modbus or ASCII, allowing for custom byte-level data transmission.

Can I mount this vertically?

Yes, this board supports both horizontal and vertical mounting to accommodate various panel configurations.

What kind of connector does it use?

It utilizes a terminal block interface for secure RS485 wiring connections.

Troubleshooting

PLC does not recognize the communication board

Verify that the board is seated correctly in the CPU slot and that the hardware configuration in TIA Portal matches the physical module.

Communication errors in Freeport mode

Check the baud rate and parity settings in your PLC project to ensure they perfectly match the settings of the external RS485 device.

Intermittent signal loss

Ensure that the RS485 cable is shielded and that the shield is grounded at one point only to prevent ground loops.

Pros and Cons

Pros

  • Seamless integration with S7-1200 CPU boards
  • Extremely lightweight at only 29g
  • Supports customizable Freeport serial communication
  • Flexible mounting options for tight cabinet spaces

Cons

  • Compatible only with S7-1200 series
  • Requires professional configuration via TIA Portal
  • Limited to RS485 communication standards

Setup, Compatibility & Care

Installation of the communication board is straightforward: it mounts directly to the front of the S7-1200 CPU. Ensure the PLC is powered off before snapping the board into the designated slot. Once physically installed, the module must be configured within the Siemens TIA Portal software environment. Navigate to the 'Device Configuration' for the specific CPU, select the communication board, and define the serial communication parameters such as baud rate, parity, and stop bits. For maintenance, keep the terminal block free of debris and ensure that shielded RS485 cabling is properly grounded to prevent interference in high-noise electrical environments.

Price History

DatePrice
Visit shop