This FuseBox RCBO (Residual Current Breaker with Overcurrent) is a Type A, Curve B single-pole cir...This FuseBox RCBO (Residual Current Breaker with Overcurrent) is a Type A, Curve B single-pole circuit protection device. It offers current ratings from 6A to 50A and has a 6kA short circuit capacity, making it compliant with the 18th edition of electrical regulations. FuseBox provides a comprehensive selection of reliable and affordable metal consumer units and protection devices, catering to the demands of modern 18th Edition electrical installations with flexible and versatile solutions. The Type A functionality allows for the detection of both AC and pulsating DC components. It is rated for a maximum cable size of 25mm² with a tightening torque of 2.5Nm and an IP20 rating. The rated operational voltage (Ue) is 230/400V. A-Rated RCBOs provide protection against AC 50Hz pulse and smooth DC currents less than 6mA. The device dimensions are (H) 114mm x (W) 18mm x (D) 70mm. This RCBO features a single module width and a standard DIN rail mount.
This guide is for electricians and electrical technicians who need to understand and use the FuseBox RCBO (Residual Current Breaker with Overcurrent). The key benefit is enhanced electrical safety and compliance with the latest regulations, offering protection against both AC and pulsating DC currents. However, proper installation by a qualified professional is crucial for optimal performance and safety.
All features
Model Part Number
Rta061630B
Brand
FuseBox
Extended Product Information
FAQs
What is the purpose of an RCBO?
An RCBO (Residual Current Breaker with Overcurrent) combines the functions of an MCB (Miniature Circuit Breaker) and an RCD (Residual Current Device) to protect against both overcurrents and earth leakage faults.
What does 'Type A' mean?
Type A RCBOs can detect both AC and pulsating DC residual currents, offering a higher level of protection.
What is the meaning of 'Curve B'?
Curve B indicates the trip characteristics of the RCBO. Curve B RCBOs are generally suitable for general-purpose applications and offer quick response to overcurrent faults.
What is the maximum cable size that can be used?
The maximum cable size is 25mm².
What is the tightening torque for the terminals?
The tightening torque for the terminals is 2.5Nm.
What is the IP rating of the RCBO?
The IP rating is IP20, meaning it protects against solid objects larger than 12.5mm but does not offer water protection.
Where can I find the installation instructions?
Installation instructions are typically provided with the product. Consult the manufacturer's documentation or a qualified electrician for guidance.
How often should I test the RCBO?
Regular testing, as recommended by electrical regulations, is important to ensure the RCBO functions correctly. The frequency of testing may vary depending on the application and local regulations. Consult with a qualified electrician for specific recommendations.
Troubleshooting
RCBO trips frequently.
Check the connected circuit for faults (e.g., short circuits, overloaded appliances). Ensure the correct RCBO rating for the circuit's load.
RCBO fails to trip when tested.
The RCBO might be faulty and should be replaced. Contact a qualified electrician to inspect and replace the device if necessary.
Difficulty mounting the RCBO on the DIN rail.
Ensure the DIN rail is compatible with the RCBO. Make sure the device is aligned correctly and clicks into place. If there's resistance, double-check the rail and RCBO for any obstructions.
Pros and Cons
Pros
Provides comprehensive electrical protection against overcurrents and earth leakage.
Complies with the latest 18th edition electrical regulations, ensuring safety.
Detects both AC and pulsating DC currents for enhanced protection.
Easy to install with a standard DIN rail mount.
Compact single-module design saves space in consumer units.
Cons
Requires professional installation by a qualified electrician.
Limited to a 16A current rating, not suitable for all circuits.
May require more frequent testing compared to standard MCBs.
Specific to FuseBox consumer units, potentially limiting compatibility in some installations.
Setup, Compatibility & Care
Installation: The RCBO should be installed by a qualified electrician, following local regulations and the manufacturer's instructions.
Mounting: The device is designed for DIN rail mounting within a compatible consumer unit.
Wiring: Ensure correct wiring according to the circuit diagram, paying attention to the input and output terminals.
Cable Size: The maximum cable size accepted is 25mm²; use the correct torque setting (2.5Nm) for the terminals.
Compatibility: This RCBO is primarily designed for use with FuseBox consumer units, ensuring compatibility. Verify the consumer unit's specifications before installation.
Testing: After installation, test the RCBO to ensure proper operation. This usually involves simulating a fault condition to verify the device trips correctly.
Maintenance: Regular inspection and testing are essential for optimal performance. Clean the device with a dry cloth if needed, and avoid using solvents or abrasive cleaners. The IP20 rating means it is protected against solid objects larger than 12.5mm but offers no water protection.