Altecnic Eres Filling Loop - 15mm

Altecnic ERES Sealed Heating System Filling Loop 15mm with Check Valve 2 x Stop Valves For Closed ...

Best current price£16.72from B&Q

One Offer

1 offer from £16.72

View price history by clicking the chart icon.

B&Q - Altecnic Eres Ca-300611 Straight 15mm Filling Loop With Check Valve And Two Stop Valves
Free delivery in 1–3 days
£16.72
Visit shop

Product Information

Full details

The Altecnic Eres Sealed Heating System Filling Loop (CA-300611) is designed for homeowners and plumbers to safely and easily fill closed central heating systems. Its key benefit is preventing contamination of the mains water supply with integrated check valves and dual isolation. A potential caveat is its 15mm compression fittings, which require compatible pipework.

All features

Model Part NumberCA-300611
BrandUnvented Components Europe

Extended Product Information

FAQs

What is a filling loop used for?

A filling loop is used to safely connect the mains cold water supply to a sealed central heating system for the purpose of topping up or refilling the system with water.

Does this filling loop comply with water regulations?

Yes, it features an integrated check valve (non-return valve) designed to prevent the contamination of the mains water supply, which is a key requirement of water supply regulations.

What size pipe does this connect to?

This filling loop is designed for 15mm pipework, using standard compression fittings.

Can I leave this filling loop permanently connected?

No, filling loops should not be left permanently connected to the system. They are designed for temporary connection during filling and should be disconnected afterward. The dual isolation valves allow for easy disconnection.

What is the benefit of dual isolation valves?

The dual isolation valves provide complete control. You can use one to allow water in to fill the system and then close both to completely isolate the filling loop from both the mains supply and the heating system.

What material is the body of the filling loop made from?

The body components are made from robust brass, suitable for heating system applications.

Troubleshooting

Water leak from compression fittings

Ensure fittings are correctly aligned and tightened. If the issue persists, the olive or pipe may be damaged and require replacement.

No water flow when valves are open

Check that both isolation valves are fully open. Ensure the mains water supply is on and that there are no blockages in the pipework or filling loop.

Check valve not preventing backflow

This is a critical safety component. If backflow is suspected, the filling loop may be faulty and should be replaced immediately.

Pros and Cons

Pros

  • Ensures water regulation compliance with its integrated check valve.
  • Offers convenient system control with dual isolation valves.
  • Durable construction with a brass body and stainless steel braided hose.
  • Easy to install on 15mm pipework without special tools.
  • Designed for reliable performance in domestic heating applications.

Cons

  • Requires 15mm pipework for connection.
  • Not suitable for open-vented heating systems.
  • The flexible hose may have a limited reach depending on the installation space.
  • Requires manual operation for filling and isolation.

Setup, Compatibility & Care Instructions

Setup:

  1. Ensure the mains water supply is turned off.
  2. Identify suitable 15mm pipework connections for both the mains water inlet and the heating system return.
  3. Use the 15mm compression fittings to connect the filling loop to the pipework. Tighten fittings securely but avoid over-tightening.
  4. Ensure the flexible hose is not kinked or stressed.
  5. Open the isolation valves slowly to fill the system as per your heating system's requirements.

Compatibility:

  • This filling loop is designed for 15mm pipework.
  • It is suitable for sealed (unvented) domestic central heating systems.
  • Ensure local water regulations are met.

Care:

  • Periodically check the isolation valve handles and the braided hose for any signs of wear or damage.
  • Keep the area around the filling loop clear of obstructions.
  • No specific cleaning agents are required; wipe with a damp cloth if necessary.

Price History

DatePrice
Visit shop