Warmer Underfloor Heating Manifold - 6 Ports - 15mm Pipe Connections - 1 Inch Ball Valves - Automatic Air Vent

PSW TRADESUPPLIERS LTD offers high quality products. Underfloor heating manifolds are able to cont...

Best current price£137.41from B&Q

All Offers

2 offers from £137.41

View price history by clicking the chart icon.

B&QB&Q - 6 Ports Water Underfloor Heating Manifold With 15mm Pipe Connections 1 Inch Ball ValvesAutomatic Air Vent Psw Tradesuppliers Ltd
Free delivery in 1–3 days
£137.41
Visit shop

Product Information

Full details

The Warmer Underfloor Heating Manifold is designed for homeowners and installers seeking efficient, multi-zone temperature control for their underfloor heating systems. Its key benefit is the ability to manage multiple zones independently, allowing for customized comfort and potential energy savings. A minor caveat is that it requires standard plumbing tools for installation and may necessitate professional help for complex setups. This comprehensive manifold system features 6 ports for efficient water distribution, 15mm pipe connections, main isolating ball valves, an automatic air vent, and a pressure gauge with a filling/drain-off valve.

All features

BrandB&Q

Extended Product Information

FAQs

What is the maximum number of zones this manifold can control?

This manifold is designed with 6 ports, allowing it to control up to six separate heating zones independently.

What size pipe connections does this manifold use?

The manifold is equipped with standard 15mm pipe connections for integration with your underfloor heating pipework.

Do I need to drain the entire heating system to perform maintenance?

No, the main isolating ball valves allow you to shut off flow to the manifold, and the filling/drain-off valve allows you to drain only the manifold or specific sections for maintenance.

How do I remove air from the underfloor heating system?

The manifold features an automatic air vent to continuously remove air. You can also manually bleed air using the filling/drain-off valve.

What is the purpose of the pressure gauge?

The pressure gauge allows you to monitor the water pressure within your underfloor heating system, ensuring it operates safely and efficiently.

Is this manifold suitable for DIY installation?

The manifold is designed for easy installation with standard plumbing tools. However, if you are not experienced with plumbing systems, professional installation is recommended to ensure a safe and effective setup.

What material is the manifold made from?

The manifold is constructed from high-quality brass for durability and long-lasting performance.

Troubleshooting

Manifold is not distributing heat evenly to all zones.

Check the flow meters on each port. Ensure they are open and adjusted correctly for each zone. Purge any trapped air from the system using the automatic air vent or manually via the drain-off valve.

Low pressure reading on the gauge.

Check the system for leaks. If no leaks are apparent, use the filling/drain-off valve to add water to the system until the pressure is in the recommended range (typically 1-2 bar).

Visible leaks from connections.

Turn off the water supply to the manifold. Inspect the connections, tighten any loose fittings, or re-seal connections with appropriate PTFE tape or sealant if necessary.

System makes gurgling noises.

This indicates trapped air. Open the automatic air vent to release trapped air. If the noise persists, manual bleeding via the drain-off valve may be required.

Difficulty in isolating a zone for maintenance.

Ensure the main isolating ball valves on the manifold are fully closed before attempting any maintenance on individual zones. If a valve is stiff, it may require lubrication or replacement.

Pros and Cons

Pros

  • Offers precise control over multiple heating zones independently.
  • Facilitates efficient water distribution for consistent underfloor heating.
  • Built with durable brass for longevity and reliable operation.
  • Includes essential components like a pressure gauge and air vent for system health.
  • Standard pipe connections simplify integration with existing systems.

Cons

  • Installation may require specific plumbing knowledge or tools.
  • Not suitable for systems requiring more than six heating zones.
  • Requires regular monitoring of pressure and occasional air bleeding.
  • Initial setup may involve a learning curve for users unfamiliar with manifolds.

Setup, Compatibility & Care Instructions

Setup:

  1. Ensure the main water supply to the underfloor heating system is turned off.
  2. Mount the manifold securely to a wall or suitable support.
  3. Connect the 15mm pipework from your underfloor heating loops to the respective ports on the manifold.
  4. Connect the water inlet and outlet pipes from your boiler or heat source to the main inlet and outlet of the manifold, ensuring the 1-inch ball valves are correctly oriented.
  5. Connect the automatic air vent and pressure gauge end units.
  6. Connect the filling/drain-off valve.
  7. Once all connections are secure, slowly open the main isolating valves and check for leaks.
  8. Fill the system with water and bleed out any air using the automatic air vent and the filling/drain-off valve.

Compatibility:

  • Compatible with standard 15mm underfloor heating pipe.
  • Suitable for use with most domestic and commercial underfloor heating systems connected to a suitable heat source (e.g., boiler, heat pump).
  • The 1-inch ball valves are designed for standard manifold connections.

Care:

  • Periodically check the pressure gauge to ensure the system pressure is within the recommended range (typically 1-2 bar).
  • Listen for any unusual noises which might indicate trapped air. If so, use the automatic air vent or manually bleed the system.
  • Inspect all connections for leaks regularly.
  • Ensure the area around the manifold is kept clean and free from debris.

Price History

DatePrice
Visit shop