The Catnic CN71A Solid Wall Lintel is ideal for external solid wall applications and narrow cavity...The Catnic CN71A Solid Wall Lintel is ideal for external solid wall applications and narrow cavity wall builds. Manufactured from galvanised steel and powder coated for enhanced durability and corrosion protection, this box profile lintel offers superior resistance to twisting under load. It is designed to support wet masonry immediately upon installation, providing a long-lasting and high-performing solution for structural openings. Key features include duplex corrosion protection, a built-in plaster key, a built-in DPC, and integral insulation. It is available in various lengths to suit different project requirements, with load capacities varying based on the span. For instance, a 900mm lintel supports 29 kN, while a 2700mm lintel supports 20 kN, with a minimum bearing of 150mm at each end.
Best current price£33.68from Materials Market Trading UK Ltd
Catnic External Solid Wall Single Leaf Angle Lintel 1800mm ANG1800Free delivery in 1–3 days£153.62Visit shop →
Product Information
Full details
This guide is for builders and DIY enthusiasts needing a reliable structural support for external solid walls or narrow cavity builds. The Catnic CN71A offers immediate wet masonry support and excellent durability, though careful selection of the correct length and load capacity is crucial for optimal performance.
All features
Model Part Number
CN71A
Brand
Catnic
Extended Product Information
FAQs
What types of walls is the Catnic CN71A suitable for?
It is specifically designed and ideal for external solid wall applications and narrow cavity wall builds.
Can I place wet masonry on the lintel immediately after installation?
Yes, the Catnic CN71A is engineered to support wet masonry immediately upon installation, allowing for continuous construction.
How do I determine the correct length and load capacity for my project?
The lintel is available in various lengths, and load capacities vary based on the span. You must calculate the required load (in kN) for your opening and choose a lintel length and type that meets or exceeds this capacity. For example, a 900mm lintel supports 29 kN, while a 2700mm lintel supports 20 kN. Always consult a structural engineer or relevant building regulations if unsure.
What is the minimum support required for the lintel?
A minimum bearing of 150mm at each end is required for proper and safe support of the lintel.
Does this lintel require additional damp proofing?
No, the Catnic CN71A features a built-in DPC (Damp Proof Course) for integrated damp protection, simplifying installation and ensuring moisture resistance.
What does 'duplex corrosion protection' mean?
It refers to the superior protection achieved by combining galvanised steel with an additional powder-coated finish, offering enhanced and long-lasting resistance against corrosion.
Does the lintel help with insulation?
Yes, it features integral insulation, which contributes to improving the thermal performance and energy efficiency of the wall opening.
Troubleshooting
Lintel appears to be deflecting or twisting after installation.
This often indicates insufficient bearing, incorrect lintel selection for the calculated load, or improper installation. Verify that the minimum 150mm bearing is achieved at each end and confirm the lintel's load capacity matches or exceeds the calculated structural load. If deflection persists, consult a structural engineer immediately.
Moisture appears above the opening after installation.
Check that the built-in DPC (Damp Proof Course) of the lintel has been properly integrated with the wall's overall damp-proofing system and that no other damp bridges exist. Ensure correct installation of any required flashing or cavity trays above the lintel.
Difficulty achieving a smooth internal plaster finish.
Ensure the built-in plaster key on the lintel is clean and free of debris. Use appropriate plastering techniques for optimal adhesion to the lintel's surface. A primer compatible with galvanised steel might be beneficial in some cases.
Lintel not fitting opening correctly.
Ensure accurate measurements of the structural opening were taken prior to purchasing. Do not attempt to force a lintel that is too long, or use one that is too short, as both can compromise structural integrity. Re-measure and acquire the correct lintel size.
Pros and Cons
Pros
High durability and corrosion resistance due to galvanised steel and powder coating.
Supports wet masonry immediately, speeding up construction.
Offers superior resistance to twisting under load, ensuring structural stability.
Includes integrated features like DPC, plaster key, and insulation for comprehensive performance and simplified installation.
Suitable for specific, demanding applications like external solid walls and narrow cavities.
Cons
Requires precise measurement and selection based on specific load and span requirements to ensure safety and performance.
Info needed: May require specific handling or lifting equipment for longer or heavier variants.
Setup, Compatibility & Care
Setup
Bearing: Ensure a minimum bearing of 150mm at each end of the lintel on solid masonry. Adequate bearing is crucial for transferring loads effectively and preventing failure.
Orientation: Install the lintel with the correct orientation as indicated by any manufacturer markings or arrows. Incorrect orientation can compromise structural integrity.
Masonry Support: The lintel is specifically designed to support wet masonry immediately upon installation. Build masonry directly onto the lintel according to structural plans.
Compatibility
Wall Types: Designed specifically for external solid wall applications and narrow cavity wall builds.
Selection: Always select the appropriate length and corresponding load capacity (measured in `kN`) based on the width of your structural opening and the calculated imposed load from the wall above. Refer to a structural engineer if unsure.
Care
Protection: The Catnic CN71A features galvanised steel and a powder-coated finish, providing duplex corrosion protection. Once installed correctly, it requires no specific ongoing maintenance.
Handling: Avoid damaging the protective coating during handling and installation, as this could compromise its corrosion resistance.