Copper Press Fit Tee Reduced Branch - Vsh Xpress - 28mm x 28mm x 22mm

The VSH XPress fitting is a press fit fitting used with a pressing tool which compresses the fitti...

Best current price£17.48from City Plumbing GB

All Offers

2 offers from £17.48 - £22.73

View price history by clicking the chart icon.

City Plumbing GBVsh Xpress Pegler Copper Press Fit Tee Reduced Branch 28Mm X 28Mm X 22Mm S25 38494.
Free delivery in 1–3 days
£17.48
Visit shop
B&QB&Q - Pegler Vsh Xpress Copper Press Fit Tee Reduced Branch 28mm X 28mm X 22mm S25 38494.
Free delivery in 1–3 days
£22.73
Visit shop

Product Information

Full details

This guide is for plumbers and installers seeking a reliable, solder-free solution for creating reduced branch connections in copper pipe systems. The VSH Xpress fitting offers a quick and secure joint using a pressing tool, eliminating the need for open flames and additional jointing materials. A key benefit is its integrated leak detection system, which reveals un-pressed fittings during testing, though it requires a specific pressing tool for installation.

All features

Model Part Number38494
BrandVsh Xpress

Extended Product Information

FAQs

What is the main advantage of using VSH Xpress fittings?

The primary advantage is the solder-free, press-fit installation method, which is faster, safer (no open flames), and more consistent than traditional soldering.

Can I use any type of copper pipe with these fittings?

No, these fittings are specifically designed for use with copper tubes that comply with BS EN 1057 standards. Using other types of pipe will void the guarantee.

What equipment do I need to install a VSH Xpress fitting?

You will need a compatible VSH Xpress pressing tool with the correct jaw sizes for the diameters of the fitting you are using (e.g., 28mm and 22mm jaws for this specific tee).

How does the system detect un-pressed fittings?

The fitting has a triangulated socket design. If the fitting is not fully pressed onto the tube, this design allows water to escape during system testing, making the un-pressed joint immediately visible.

What is the guarantee period for VSH Xpress fittings?

VSH Xpress fittings come with a 25-year guarantee when installed correctly with copper tube compliant to BS EN 1057.

Are these fittings approved for potable water systems?

Yes, VSH Xpress fittings hold WRAS and DVGW approval, confirming their suitability and safety for potable water applications.

Can I reuse a VSH Xpress fitting after pressing it?

No, once a VSH Xpress fitting is pressed onto a copper tube, it creates a permanent joint and cannot be reused. If removal is necessary, the fitting and a section of the pipe will need to be replaced.

Troubleshooting

Fitting does not press correctly

Ensure the correct pressing jaw size is used for the fitting diameter. Verify the pressing tool is fully charged and operational. Check that the copper tube is inserted to the correct depth and is not damaged. Consult the pressing tool manual for troubleshooting steps.

Leak detected during system testing

The leak is likely due to an un-pressed or incompletely pressed fitting. Identify the leaking joint. If it's an un-pressed fitting, repress it correctly. If the fitting appears pressed but still leaks, the tube or fitting may be damaged; remove and replace the fitting and tube section.

Difficulty inserting tube into fitting

Check the end of the copper tube for any damage, burrs, or deformation. Ensure the tube is round. Deburr and re-cut the tube end if necessary. Lightly lubricate the tube end and fitting socket with a compatible lubricant if recommended by the manufacturer.

Fitting appears loose after pressing

This indicates an incomplete press. The fitting must be removed (if possible without damaging the tube) and replaced, or the entire pipe section should be replaced. Ensure the correct tool and jaw size are used for subsequent attempts.

Pros and Cons

Pros

  • Fast and efficient installation compared to traditional soldering methods.
  • Enhanced safety due to the absence of open flames.
  • Reliable and leak-free joints when properly pressed.
  • Integrated visual indicator for un-pressed fittings during testing.
  • Durable construction suitable for demanding plumbing applications.
  • Long-term peace of mind with a 25-year guarantee.

Cons

  • Requires a specialized press fitting tool for installation.
  • Higher initial cost for the fitting and required tool compared to solder fittings.
  • Limited to use with copper tubes conforming to BS EN 1057.
  • Less forgiving of minor imperfections on the copper tube end compared to soldered joints.
  • Availability of specific sizes and configurations might be limited compared to traditional fittings.

Setup, Compatibility & Care

Setup and Installation:

  1. Tube Preparation: Ensure the copper tube (to BS EN 1057) is clean, free from burrs, and cut to the correct length. Use a deburring tool to smooth the inside and outside edges of the tube.
  2. Marking: Mark the insertion depth on the copper tube using a depth gauge or marker. This ensures the tube is inserted fully into the fitting.
  3. Insertion: Insert the copper tube straight into the VSH Xpress fitting up to the marked depth.
  4. Pressing: Using the appropriate VSH Xpress pressing tool and jaw size for the fitting (28mm for the main run, 22mm for the branch), align the tool with the fitting and complete the pressing cycle as per the tool manufacturer's instructions. A full, audible 'click' often indicates a completed press.

Compatibility:

  • Tube Material: Exclusively compatible with copper tubes manufactured to BS EN 1057 (Table X, Y, or Z temper). Using other tube types or materials will void the guarantee and may compromise the joint.
  • Pressing Tool: Requires a compatible VSH Xpress pressing tool with the correct jaw sizes for 28mm and 22mm fittings.
  • Environment: Suitable for use in potable water, heating, and cooling systems within the specified temperature and pressure ratings (refer to manufacturer's technical data).

Care and Maintenance:

  • These fittings are maintenance-free once installed. Regular system checks for pressure and temperature are recommended as part of standard building maintenance.
  • Avoid using abrasive cleaners or solvents on the fittings. A light wipe with a damp cloth is sufficient if external cleaning is necessary.