Siemens SIMATIC ET 200SP Digital Output Module 8x 24V DC

SIMATIC ET 200SP, Digital Output Module, DQ 8x 24V DC/0.5A Standard, Source Output (PNP,P-switchin...

Best current price£48.00from eBay

All Offers

14 offers from £48.00 - £317.39

View price history by clicking the chart icon.

eBaySiemens SIMATIC ET 200SP 6ES7132-6BF01-0BA0
£13.20 delivery
£48.00
Visit shop
Tameson UKSiemens Fieldbus Decentralized Peripheral - Digital Input And Output Module - 6Es71326bf010ba0
Free delivery in 1–3 days
£73.91
Visit shop
Rapid Online - Rapid Electronics Ltd.Siemens 6ES71326BF010BA0 SIMATIC ET 200SP digital output module 8x...
Free delivery in 1–3 days
£80.26
Visit shop

Used Offers

10 offers from £15.85 - £43.32

View price history by clicking the chart icon.

eBaySIEMENS 6ES7132-6BF00-0BA0, Digital output module, E06
£29.14 delivery
£15.85
Visit shop

Product Information

Full details

The Siemens SIMATIC ET 200SP Digital Output Module (DQ 8x 24V DC/0.5A) is designed for automation professionals and engineers seeking a flexible, space-saving, and reliable I/O system. Its key benefit is the high level of integration and modularity, allowing for quick expansion and adaptation to various automation tasks. A potential caveat is the need for compatible BU (Base Unit) types and specific packaging units.

All features

BrandSiemens

Extended Product Information

FAQs

What is the maximum current per digital output channel?

Each of the 8 digital output channels can handle a maximum current of 0.5A at 24V DC.

What type of output is this module?

This is a source output module, also known as PNP or P-switching.

Can I replace modules while the system is running?

Yes, the SIMATIC ET 200SP system supports 'multi-hot swapping', allowing for the quick and easy exchange of modules without powering down the entire station.

What does 'Substitute Value Output' mean?

Substitute Value Output allows the module to output a pre-defined safe value if communication with the central controller is lost, ensuring a controlled state for connected devices.

Which Base Unit (BU) is required for this module?

This module requires a BU type A0.

What types of diagnostics does this module provide?

It provides diagnostics for short circuits to L+ and M (ground), and wire breaks on the output channels.

Is this module suitable for high-power loads?

With a 0.5A limit per channel, it is suitable for controlling standard industrial devices like solenoid valves and indicator lights. For higher power loads, external relays or contactors would be necessary.

Troubleshooting

Module not recognized by the system

Verify the module is correctly seated in the Base Unit. Check Base Unit power and communication wiring. Ensure the module is configured correctly in the engineering software and the correct Base Unit type (A0) is used.

Digital outputs are not switching

Check the 24V DC supply voltage to the module. Verify the output load is within the 0.5A limit. Inspect wiring for breaks or shorts. Confirm the output signal is active in the PLC program.

Diagnostic alarm for short circuit to L+ or M

Disconnect the load from the specific output channel. Check the output wiring for a short circuit to the positive supply (L+) or ground (M). If the alarm persists with no load connected, the module itself may be faulty.

Diagnostic alarm for wire break

Inspect the wiring connected to the affected output channel for breaks or loose connections. Ensure the load connected to the output is not drawing excessive current, which can sometimes be misinterpreted as a wire break.

Pros and Cons

Pros

  • Compact, space-saving design ideal for limited control cabinet space.
  • High channel density for efficient I/O expansion.
  • Integrated diagnostics reduce downtime and simplify fault finding.
  • Modular design allows for quick and easy maintenance and upgrades.
  • PNP output simplifies wiring in many common industrial setups.
  • Siemens' reputation for industrial automation reliability and future security.

Cons

  • Requires specific BU type A0 and packaging units for proper integration.
  • 0.5A per channel may be insufficient for high-power loads without intermediate relays.
  • Machine-translated documentation might require careful review for nuanced technical details.
  • Primarily designed for integration within the SIMATIC ET 200SP system, limiting standalone use.

Setup, Compatibility & Care

Setup:

  1. Module Installation: The module slots into a compatible SIMATIC ET 200SP Base Unit (BU type A0 specifically noted). Ensure the Base Unit is correctly wired and powered.
  2. Connection: Connect the 24V DC supply and the digital output signals to the appropriate terminals on the Base Unit. Ensure proper grounding.
  3. Configuration: Configure the module within the Siemens TIA Portal or compatible engineering software, assigning it to the appropriate address space.

Compatibility:

  • System: Designed exclusively for the SIMATIC ET 200SP distributed I/O system.
  • Base Units (BUs): Requires a BU type A0.
  • Communication: Compatible with various communication protocols supported by the ET 200SP interface modules (e.g., PROFINET, PROFIBUS).
  • Voltage: Operates with a 24V DC power supply.

Care:

  • Environment: Install in a control cabinet with adequate ventilation to prevent overheating.
  • Cleaning: If necessary, clean with a dry or slightly damp, lint-free cloth. Avoid solvents or abrasive cleaners.
  • Handling: Handle modules with care to avoid electrostatic discharge (ESD). Ensure proper grounding when working with modules.