Warmer Underfloor Heating Manifold - 5 Ports - 15mm Pipe Connections

PSW TRADESUPPLIERS LTD offers high quality products.Underfloor heating manifolds are able to contr...

Best current price£120.34from B&Q

All Offers

2 offers from £120.34

View price history by clicking the chart icon.

B&QB&Q - 5 Ports Water Underfloor Heating Manifold With 15mm Pipe Connections 1 Inch Ball ValvesAutomatic Air Vent Psw Tradesuppliers Ltd
Free delivery in 1–3 days
£120.34
Visit shop

Product Information

Full details

This Warmer Underfloor Heating Manifold by B&Q is designed for homeowners and professional installers seeking precise control over multi-zone underfloor heating systems. Its key benefit is the ability to regulate temperature independently in up to five zones, ensuring comfort and efficiency. A potential consideration is its 15mm pipe connections, which may require specific fittings depending on your existing system. The manifold features durable brass construction, integrated flow and pressure gauges, automatic air vents, and main isolating valves for comprehensive system management and ease of maintenance.

All features

BrandB&Q

Extended Product Information

FAQs

What is the maximum number of heating zones this manifold can control?

This manifold is designed to control up to 5 heating zones independently.

What size pipe connections does this manifold have?

The manifold features 15mm pipe connections for integration into your underfloor heating system.

Do I need to manually vent air from the system?

No, this manifold is equipped with an automatic air vent end unit that efficiently removes trapped air.

How do I monitor the system's water pressure?

The manifold includes a pressure gauge end unit that allows for convenient monitoring of the system pressure.

Is this manifold suitable for all types of underfloor heating systems?

It is suitable for water-based underfloor heating systems and requires 15mm pipe connections. Compatibility with specific boiler types or control systems should be confirmed.

What maintenance is required for this manifold?

Basic maintenance includes periodic checks of the pressure gauge, ensuring air vents are clear, and inspecting connections for leaks. The filling/drain off valve can be used for system flushing if needed.

Can I install this myself?

The manifold is designed for easy installation with standard plumbing tools, making it accessible for DIY enthusiasts. However, professional installation is recommended for optimal performance and to ensure system integrity.

Troubleshooting

Manifold is not distributing heat evenly across zones.

Check the flow control on each zone to ensure it is open correctly. Use the flow gauges to balance the water flow to each loop. Ensure air has been fully purged from the system.

Pressure gauge shows low pressure.

Check the main water supply and the filling/drain off valve. The system may need to be refilled. Inspect for leaks if pressure continues to drop after refilling.

Air is constantly accumulating in the system.

Ensure the automatic air vent is functioning correctly. Check for potential air ingress points in the system pipework or connections. Consider a system flush if air is persistent.

Leaking connections.

Turn off the water supply. Tighten the leaking connection. If the leak persists, check the integrity of the pipework and the fitting; re-seal or replace as necessary.

Pros and Cons

Pros

  • Precise multi-zone temperature control for customized comfort.
  • Integrated monitoring tools (flow, pressure) simplify system management.
  • Durable brass construction ensures long-term reliability.
  • Includes essential components like air vents and drain valves for complete functionality.
  • Suitable for both residential and commercial underfloor heating applications.

Cons

  • Requires 15mm pipe connections, which might necessitate adapters for non-standard systems.
  • As a 5-port unit, it may be overkill for very small or single-zone systems.
  • Professional installation is recommended for optimal performance and to avoid leaks.

Setup, Compatibility & Care

Setup:

  1. Ensure the main water supply to the heating system is turned off.
  2. Connect the 15mm pipework from your underfloor heating loops to the designated ports on the manifold.
  3. Connect the primary flow and return pipes from your boiler or heat source to the inlet and outlet on the manifold.
  4. Purge air from the system using the automatic air vent and filling/drain off valve.
  5. Gradually fill the system, monitoring the pressure gauge to reach the recommended operating pressure (typically 1-2 bar).
  6. Check all connections for leaks.

Compatibility:

  • This manifold is designed for use with standard underfloor heating systems.
  • Requires 15mm pipe connections. Ensure your pipework is compatible or use appropriate adapters.
  • Suitable for use with water-based heating systems.

Care:

  • Periodically check the pressure gauge to ensure it is within the optimal range.
  • Listen for any unusual noises that might indicate air in the system; if so, use the automatic air vent to release it.
  • Inspect all connections annually for any signs of leakage or corrosion.
  • Keep the manifold area clean and free from dust and debris.