Bilge Pump Non Return Valve - AB Tools - AQ353

Prevents back flow of water in the bilge. Mounts as close to the strainer as possible and lock up ...

Best current price£25.72from eBay

One Offer

1 offer from £25.72

View price history by clicking the chart icon.

eBayBilge Pump Non Return Valve One Way Outlet 25mm or 38mm Hose Back Flow
Free delivery in 1–3 days
£25.72
Visit shop

Product Information

Full details

This AB Tools Bilge Pump Non Return Valve (AQ353) is designed for boat owners and marine maintenance professionals to prevent the backflow of water into the bilge, ensuring your bilge pump system remains effective. Its simple, straight-through design and durable construction offer a reliable safety feature. However, careful installation close to the pump strainer is crucial for optimal performance.

All features

Model Part NumberAQ353
BrandAB Tools

Extended Product Information

FAQs

What is the main purpose of this non-return valve?

Its primary purpose is to prevent water that has been pumped out of the bilge from flowing back into the hull, ensuring the bilge remains dry and reducing the workload on the bilge pump.

Can this valve be used with different sizes of bilge hose?

Yes, it is designed to be compatible with both 25mm (1 inch) and 38mm (1.5 inch) internal diameter hoses. The 25mm outlets can be used directly, or the larger spigots can be adapted by cutting at the pre-moulded groove if using a 38mm hose.

What materials is the valve made from?

The valve features a top-quality polyamide body and a nitrile gasket, which is resistant to fuel.

How should I orient the valve during installation?

For best performance, install the valve in line with the hose, allowing water to flow through it in the direction of pumping. Mounting it as close to the pump as possible is recommended.

Is this valve suitable for high-pressure applications?

This valve is designed for standard bilge pump applications and is not intended for high-pressure systems. Its straight-through design prioritizes flow over pressure resistance.

How often should I inspect the valve?

It is recommended to inspect the valve periodically, especially before extended periods of non-use or after heavy weather, to ensure it is free from debris and functioning correctly.

What happens if the nitrile gasket is damaged?

A damaged gasket may compromise the valve's ability to prevent backflow. If the gasket is cracked or worn, it should be replaced to maintain the system's effectiveness.

Troubleshooting

Bilge pump still cycles frequently after installation.

Verify the non-return valve is installed correctly and oriented to prevent backflow. Ensure it is mounted as close to the pump as possible and that the hose connections are secure. Check for any blockages within the valve or the hose.

Water leakage around hose connections.

Ensure hose clamps are tightened appropriately and that the hose is properly seated onto the valve's spigots. Inspect the hose for any damage that may prevent a proper seal.

Valve mechanism seems stiff or stuck.

Disconnect the hose and inspect the valve's internal components for debris or sediment. Clean gently with a damp cloth and reassemble. Ensure the valve is not installed under undue stress from the hoses.

Reduced water flow from the bilge pump.

Confirm the valve is installed in the correct orientation for water flow. Check for any obstructions within the valve itself. Ensure the hose size is appropriate and not causing excessive backpressure.

Pros and Cons

Pros

  • Reliably prevents water backflow into the bilge.
  • Durable, fuel-resistant materials ensure longevity.
  • Adaptable to common hose sizes (25mm and 38mm).
  • Straight-through design minimizes flow restriction.
  • Enhances the safety and efficiency of bilge pump systems.

Cons

  • Requires precise installation close to the pump strainer for best results.
  • May require cutting hose adapters, adding a step to installation.
  • Not suitable for systems requiring high-pressure or continuous flow.
  • Nitrile gasket may degrade with prolonged exposure to certain aggressive chemicals beyond fuel.

Setup, Compatibility & Care

Setup:

  1. Identify Location: Choose a mounting point as close as possible to the bilge pump's strainer.
  2. Determine Hose Size: This valve is designed for 25mm (1 inch) or 38mm (1.5 inch) internal diameter hose.
  3. Adapt Hose Size (if needed): If using a 25mm hose, ensure the 38mm outlets are still attached. If using a 38mm hose, you may need to cut off the 25mm spigot. A pre-moulded groove indicates the cutting point for adapting to 25mm (1 inch) fittings when using a 38mm hose.
  4. Install Valve: Securely attach the valve to the hose, ensuring a watertight seal on both ends.
  5. Test: Operate the bilge pump to confirm water is being expelled and not returning.

Compatibility:

  • Hose Sizes: Compatible with 25mm (1 inch) and 38mm (1.5 inch) internal diameter hoses.
  • Fluid Type: Suitable for bilge water, which may contain small amounts of fuel or oil due to the nitrile gasket.

Care:

  • Regular Inspection: Periodically check the valve for any signs of wear, damage, or blockage.
  • Cleaning: If flow is restricted, disconnect the hose and check the valve mechanism and gasket for debris. Clean with a damp cloth. Avoid harsh solvents.
  • Gasket Condition: Ensure the nitrile gasket remains pliable and free from cracks. Replace if damaged.

Price History

DatePrice
Visit shop