The Eaton FAZ-S6/2 is a miniature circuit breaker (MCB) designed for reliable overcurrent protection in electrical systems. It is ideal for residential, commercial, and industrial applications requiring precise tripping characteristics. While offering robust protection, its Type S characteristic means it is designed for specific applications and may not be suitable for all circuit protection needs.
| Series | xEffect |
|---|---|
| Model Part Number | 278809 |
| Brand | Eaton |
Its main purpose is to protect electrical circuits from overcurrents and short circuits, preventing damage to wiring and equipment, and reducing the risk of fire.
The 'Type S' characteristic refers to the breaker's tripping curve. It is designed to tolerate higher inrush currents for a short period before tripping, compared to a standard Type B curve, making it suitable for loads with moderate startup currents without causing nuisance tripping.
The Eaton FAZ-S6/2 has a rated short-circuit breaking capacity (Icu) of 10 kA according to IEC 60947-2 at 230 V and 400 V.
Yes, the breaker is rated for 60V DC, making it suitable for certain low-voltage DC applications in addition to its primary 230V AC use.
The breaker can accommodate conductor cross-sections from 1mm² up to 25mm², for both solid and multi-wired (stranded) conductors.
No, it has an IP20 rating, which means it is protected against solid objects but not against water. It should be installed in a suitable enclosure to protect it from moisture and dust.
To reset the breaker, push the operating handle fully to the 'OFF' position, then push it to the 'ON' position. If it trips again immediately, there is likely a persistent fault on the circuit.
This indicates a short circuit in the connected load or wiring. Turn off all devices on the circuit, reset the breaker. If it still trips, there is a fault in the wiring. If it does not trip, turn devices back on one by one to identify the faulty device.
This could be due to a 'nuisance trip' caused by a brief inrush current not handled by the Type S characteristic, or a developing fault. Check for loose connections, overheating, or a faulty appliance. Ensure the load does not exceed the 6A rating.
This is a serious safety issue. Immediately de-energize the circuit and replace the faulty breaker. Do not use the circuit until the breaker is replaced.
Ensure the DIN rail is properly installed and the breaker is seated correctly. Check for obstructions. If stiffness persists, the internal mechanism may be compromised; consider replacement.
Setup:
Compatibility: