UNI-T Clamp Meter - UT204R


Best current price£52.42from Tameson UK
Best offers
Shopping.co.uk recommended and popular offers
Uni-T Ut204r Clamp Meter
Visit shop

Best current price£52.42from Tameson UK
Shopping.co.uk recommended and popular offers
Uni-T Ut204r Clamp Meter
Visit shop2 offers from £52.42 - £139.45
View price history by clicking the chart icon.
The UNI-T UT204R is a True-RMS current clamp meter designed for electricians, technicians, and DIY enthusiasts who need to accurately measure AC and DC current up to 600A. Its key benefit is the combination of clamp-on current measurement with a comprehensive multimeter, offering versatility for various electrical tasks. A potential caveat is that its advanced features might require some familiarity with electrical testing equipment.
| Model Part Number | UT204R |
|---|---|
| Brand | UNI-T |
True-RMS (Root Mean Square) provides more accurate readings of voltage and current, especially for AC signals that are not pure sine waves (e.g., from inverters or variable frequency drives). Standard 'average' meters can be inaccurate in these situations.
Yes, the UNI-T UT204R is capable of measuring both AC and DC current up to 600A using the clamp jaws.
Connect the included Type K thermocouple to the appropriate terminals on the meter, select the temperature function, and place the probe of the thermocouple on the surface or in the environment you wish to measure.
The test leads are used for measuring AC/DC voltage, resistance, capacitance, and frequency. They are also used in conjunction with the thermocouple for temperature measurements.
Always ensure the meter is in good condition, test leads are not damaged, and the correct function and range are selected. Never exceed the maximum voltage or current ratings. For current measurements, clamp only around a single conductor.
The backlight typically activates when a button is pressed or a measurement is initiated and may have a timeout to conserve battery life. Refer to the user manual for specific behavior.
Check if the battery is low or depleted. Replace with a new battery. Ensure the battery is installed correctly.
Ensure the correct function and range are selected. Verify test leads are securely connected and not damaged. For current measurements, ensure the clamp is around only one conductor. Check for low battery.
Verify the circuit is de-energized before testing. Ensure the meter is set to the continuity function. Check the test leads and connections. The resistance might be too high for continuity detection.
The measured value exceeds the selected range. Select a higher range or a more appropriate function.
Setup:
Compatibility: The UT204R is designed for general electrical work and is compatible with standard electrical systems. Ensure measurements do not exceed the meter's specified maximum voltage or current ratings.
Care: