Siemens SENTRON Circuit Breaker - 4A - 1P+N - 6kA - Curve C

SENTRON 5SY miniature circuit breaker designed for reliable short-circuit and overload protection ...

Best current price£45.55from Tameson UK

All Offers

2 offers from £45.55 - £89.64

View price history by clicking the chart icon.

Tameson UKSiemens 5Sy6504-7 Circuit Breaker 4A 1P+N 6Ka - 5Sy65047
Free delivery in 1–3 days
£45.55
Visit shop
eBaySIEMENS 5SY6504-7 Circuit breaker
£13.20 delivery
£89.64
Visit shop

Product Information

Full details

The Siemens SENTRON 5SY6 miniature circuit breaker is designed for electricians and homeowners seeking reliable protection against overloads and short circuits in residential and industrial electrical installations. Its primary benefit is ensuring the safety of electrical equipment and preventing damage caused by electrical faults. A key consideration is its specific current rating and breaking capacity, which must match the circuit's requirements. This device offers dependable protection with a 4A rating, 1+N pole configuration, a C tripping characteristic, and a 6kA breaking capacity, featuring a tool-free installation mechanism and versatile terminals.

All features

SeriesSENTRON
Model Part Number5SY6504-7
BrandSiemens

Extended Product Information

FAQs

What is the primary function of this circuit breaker?

The Siemens SENTRON 5SY6504-7 circuit breaker is designed to protect electrical circuits from damage caused by overloads and short circuits, automatically disconnecting the power to prevent fire hazards and equipment damage.

What does the 'C' characteristic mean?

A 'C' characteristic indicates that the breaker is designed to tolerate moderate inrush currents (e.g., from motors or lighting) without tripping, but will still trip quickly on short circuits. This makes it suitable for general commercial and residential applications.

Can this breaker be used for DC circuits?

The breaker has a DC voltage rating of 72V. While it can be used in low-voltage DC applications, its primary design and testing are for 230V AC circuits. Ensure the DC application voltage is within its rated limits.

How do I install this circuit breaker?

The breaker features a tool-free installation mechanism. It simply slides onto a standard 35mm DIN rail. Connect the input wires to the dual-chamber terminals and ensure a secure attachment.

What is the breaking capacity (kA) of this device?

This circuit breaker has a rated short-circuit breaking capacity (Icn) of 6 kA according to EN 60898 and 30 kA (Icu) according to IEC 60947-2 at 230V and 400V.

What is the advantage of the 1+N pole configuration?

The 1+N pole configuration disconnects both the live and neutral conductors simultaneously during a fault, offering enhanced safety compared to single-pole breakers, especially in certain earthing arrangements.

What size conductors can be connected?

The dual-chamber terminals can accommodate both multi-wired and solid-core conductors with cross-sections ranging from 0.75 mm² to 35 mm².

Troubleshooting

Breaker trips immediately upon re-energization.

This indicates a persistent overload or a short circuit in the connected wiring or appliance. Check all connections and appliances for faults. Ensure the connected load does not exceed the breaker's 4A rating.

Breaker does not trip when a fault is simulated.

The breaker may be faulty or incorrectly installed. Disconnect power and inspect installation. If the issue persists, the breaker may need replacement. Professional testing is recommended.

Difficulty attaching breaker to DIN rail.

Ensure the DIN rail is correctly mounted and standard. Check that the breaker's mounting clips are clear and unobstructed. Ensure the breaker is aligned properly before attempting to slide it on.

Overheating at the terminals.

This can be caused by loose connections or using undersized conductors. Ensure conductors are stripped to the correct length and securely tightened in the terminals. Use conductors within the specified cross-section range (0.75-35 mm²).

Pros and Cons

Pros

  • Provides reliable overload and short-circuit protection.
  • Easy and quick installation with the tool-free mounting mechanism.
  • Versatile terminal design accommodates various conductor types and busbars.
  • C characteristic is suitable for most general applications with moderate inrush currents.
  • Compact size saves space in electrical enclosures.

Cons

  • Limited to a 4A current rating, not suitable for high-power circuits.
  • Breaking capacity of 6kA might be insufficient for very high fault current industrial environments.
  • Requires compatibility check for specific electrical system requirements.
  • Primarily designed for AC circuits; DC voltage rating is lower (72V DC).

Setup, Compatibility & Care

Setup:

  1. Ensure the power supply to the circuit is completely de-energized.
  2. Slide the circuit breaker onto a standard DIN rail (35mm).
  3. Use the double slide mechanism for a secure, tool-free attachment.
  4. Connect the input conductors (live and neutral) to the appropriate terminals. The dual-chamber terminals accept solid-core and stranded conductors up to 35 mm².
  5. Connect any busbars if applicable.
  6. For the 1+N pole, ensure both the live and neutral conductors are correctly terminated.
  7. Close the panel cover securely.
  8. Re-energize the circuit and test the breaker function by toggling the switch.

Compatibility:

  • Mounting: Compatible with standard 35mm DIN rails.
  • Conductors: Suitable for solid and stranded conductors from 0.75 to 35 mm².
  • Busbars: Compatible with standard busbar systems.
  • Voltage: Designed for 230V AC systems. Note the DC rating of 72V.
  • Environment: IP20 degree of protection, suitable for dry indoor environments. Ambient operating temperature: -25 to 55 °C.
  • Accessories: Additional equipment can be mounted, though specific compatibility should be verified.

Care:

  • Cleaning: Keep the circuit breaker clean and free from dust and debris. Use a dry cloth for cleaning. Avoid using liquids or solvents.
  • Inspection: Periodically inspect the breaker for any signs of physical damage or overheating.
  • Operation: Test the breaker's tripping function periodically (e.g., annually) by manually switching it off and on. Professional testing may be required for critical applications.
  • Environment: Ensure the breaker operates within its specified temperature and humidity ranges to maintain performance and longevity.