Lewden Miniature Circuit Breaker - Triple Pole - 10kA - C Curve

Introducing Lewden's 6A to 63A Triple Pole 10kA C Curve MCB, specifically designed and tested for ...

Best current price£28.33from City Plumbing GB

All Offers

2 offers from £28.33 - £34.50

View price history by clicking the chart icon.

City Plumbing GBLewden Triple Pole Type C 10Ka Curve Miniature Circuit Breaker E10-3C32
Free delivery in 1–3 days
£28.33
Visit shop
B&QB&Q - 32A Triple Pole 10Ka C Curve Mcb
Free delivery in 1–3 days
£34.50
Visit shop

Product Information

Full details

This Lewden 6A to 63A Triple Pole 10kA C Curve MCB is designed for users of Lewden distribution boards seeking reliable circuit protection. Its key benefit is ensuring safety against overloads and short circuits within Lewden systems. A caveat is that it is specifically tested and recommended for use with Lewden branded distribution boards. This thermal magnetic miniature circuit breaker offers dependable protection for circuits rated up to 10kA, featuring a C Curve trip characteristic for inductive loads, and is suitable for 3-phase applications.

All features

Model Part NumberE10-3C32
BrandLewden

Extended Product Information

FAQs

What does '10kA C Curve' mean?

'10kA' refers to the breaking capacity, meaning it can safely interrupt a fault current of up to 10,000 Amperes. 'C Curve' indicates its tripping characteristic, designed to trip between 5 to 10 times the rated current, making it suitable for circuits with moderate inductive loads or inrush currents.

Can I use this MCB with distribution boards from other brands?

While it might physically fit, this MCB is specifically designed and tested for optimal performance and safety with Lewden branded distribution boards. Compatibility and reliability with other brands are not guaranteed.

What is the difference between a C Curve and other trip curves?

C Curve MCBs are for circuits with moderate inrush currents (e.g., small motors, fluorescent lighting). B Curve trips at 3-5 times rated current (e.g., resistive loads like heaters), and D Curve trips at 10-20 times rated current (e.g., large motors, transformers).

Is this MCB suitable for domestic lighting circuits?

For most domestic lighting circuits, a single-pole B Curve MCB is typically used. This triple-pole C Curve MCB is more suited for 3-phase applications or circuits with higher inrush currents.

How do I reset a tripped MCB?

To reset a tripped MCB, first identify and resolve the cause of the overload or short circuit. Then, push the MCB's lever firmly upwards to the 'ON' position.

What standards does this MCB comply with?

This MCB complies with the BS EN 60898-1 standard.

What is the rated operating voltage?

The rated operating voltage is 230-400V~.

Troubleshooting

MCB trips frequently on startup

The circuit may have a higher inrush current than the C Curve is designed for. Consider if a D Curve MCB is more appropriate for this specific load, or investigate the load itself for faults.

MCB does not trip under fault conditions

Verify correct wiring and connections. Ensure the MCB is correctly rated for the circuit. If the issue persists, the MCB may be faulty and should be replaced by a qualified electrician.

MCB feels loose on the DIN rail

Ensure the DIN rail is properly installed and secured. Check the mounting clip on the MCB and ensure it is engaging correctly with the rail. Re-seat the MCB firmly.

MCB won't switch on after tripping

Identify and rectify the cause of the trip (overload or short circuit). Once the fault is cleared, reset the MCB by pushing the lever fully up.

Pros and Cons

Pros

  • Specifically designed and tested for Lewden distribution boards, ensuring compatibility and optimal performance.
  • Provides reliable protection against overloads and short circuits.
  • C Curve characteristic is suitable for a range of applications, including those with moderate inrush.
  • Triple pole design is efficient for 3-phase systems.
  • Robust 10kA breaking capacity offers a high level of safety.

Cons

  • Primarily recommended for use with Lewden branded distribution boards; compatibility with other brands may vary.
  • C Curve may not be ideal for very high inrush current loads, where a D Curve might be more appropriate.
  • Installation requires knowledge of electrical wiring and safety standards.

Setup, Compatibility & Care

Setup:

  1. Ensure the main power supply to the distribution board is isolated.
  2. Mount the MCB securely onto a standard DIN rail within a compatible Lewden distribution board.
  3. Connect the incoming live conductors to the appropriate terminals on the triple poles.
  4. Connect the outgoing circuit conductors to the load terminals.
  5. Ensure all connections are tight and meet local electrical regulations.
  6. Restore power supply and test the MCB's functionality.

Compatibility:

  • This MCB is designed and tested for use with Lewden branded distribution boards.
  • Suitable for circuits with rated currents from 6A up to 63A.
  • Compatible with 3-phase power systems.
  • Designed for use with cables of ø1-25 mm².

Care:

  • This is a maintenance-free device under normal operating conditions.
  • Periodically check for dust accumulation on the unit and clean with a dry cloth if necessary.
  • Ensure ventilation around the distribution board is adequate.
  • Avoid operating the switch in excessively dusty or humid environments.