ABB Circuit Breaker - S200 - 1P+N - 2A B-Curve - 6kA

Best current price£47.59from Tameson UK
Best offers
Shopping.co.uk recommended and popular offers
Abb System Pro M Compact Circuit Breaker - 2Cds251103r0105
Visit shop
Best current price£47.59from Tameson UK
Shopping.co.uk recommended and popular offers
Abb System Pro M Compact Circuit Breaker - 2Cds251103r0105
Visit shop2 offers from £47.59 - £50.43
View price history by clicking the chart icon.
This guide is for electricians and DIY enthusiasts requiring reliable overcurrent protection. The ABB 2CDS251103R0025 offers compact, 6kA breaking capacity for AC/DC circuits in a 2-module width, ensuring safety and compliance. A key caveat is its specific B-curve characteristic, which dictates its application suitability.
| Series | S200 |
|---|---|
| Model Part Number | 2CDS251103R0025 |
| Brand | ABB |
The 'B' curve indicates the tripping characteristic. A B-curve breaker trips between 3 to 5 times the nominal current. It's typically used for lighting circuits, socket outlets, and protection of electronic equipment with low inrush currents.
This circuit breaker has a breaking capacity of 6kA (kiloamperes), meaning it can safely interrupt fault currents up to 6000 amperes according to EN 60898 standards.
Yes, this circuit breaker is suitable for DC applications as well as AC applications, provided the voltage rating for DC is not exceeded.
The nominal current rating for this specific model (S201-B2NA) is 2 Amperes (2A).
Consider the type of load, its expected inrush current, and the overall circuit protection requirements. For loads with low inrush current (like lighting or electronics), the B-curve is suitable. For loads with moderate inrush current (like small motors), a C-curve might be better. Always consult electrical codes and a qualified electrician if unsure.
'1P + NA' means the circuit breaker protects one pole (phase) plus the neutral conductor. It's a single-pole breaker with integrated neutral switching.
This circuit breaker is 2 modules wide, referring to the standard width of electrical components used on DIN rails.
This indicates a short circuit in the connected load or wiring. Disconnect the load and check wiring for faults. If the breaker trips with no load connected, the breaker itself may be faulty.
Ensure the breaker is correctly rated for the circuit. Test the breaker's trip function manually. If it fails to trip during a tested fault, replace the breaker immediately.
Ensure all terminal connections are tightened to the correct torque specification. Loose connections can cause resistance and heat buildup. Check for damaged wiring.
Verify the load characteristics. The B-curve might be too sensitive for the connected equipment's inrush current. Consider if a C or D curve breaker is more appropriate, or if the load itself is causing intermittent issues.