Omron Limit Switch - D4N-4120

This Omron D4N series snap action limit switch features a 1NC/1NO contact configuration and a resi...

Best current price£18.71from Tameson UK

All Offers

3 offers from £18.71 - £78.62

View price history by clicking the chart icon.

Tameson UKOmron Gold Safety Products Limit Switch - D4n4120
Free delivery in 1–3 days
£18.71
Visit shop
Blueperry agriculture (UK)Omron Limit Switch, Roller Lever D4n4120
Free delivery in 1–3 days
£36.46
Visit shop
eBayOMRON D4N-4120 Limit switch
£13.20 delivery
£78.62
Visit shop

Product Information

Full details

The Omron D4N-4120 is a robust snap action limit switch designed for industrial applications requiring reliable position detection. It offers a versatile 1NC/1NO contact configuration and a durable resin roller lever actuator, making it ideal for automated machinery and control systems. A key benefit is its high contact reliability due to standardized gold-clad contacts. However, its fixed conduit size might require specific installation considerations.

All features

SeriesD4N
Model Part NumberD4N-4120
BrandOmron

Extended Product Information

FAQs

What is the primary function of a limit switch?

A limit switch is an electromechanical device used to detect the presence or absence of an object, or the position of a moving part. It converts a physical motion into an electrical signal.

What does '1NC/1NO' contact configuration mean?

This means the switch has one normally closed (NC) contact that is open when the switch is not actuated, and one normally open (NO) contact that is closed when the switch is not actuated.

What is the significance of the IP67 rating?

The IP67 rating indicates that the switch is protected against dust ingress (the '6') and can withstand immersion in water up to 1 meter for 30 minutes (the '7').

Can I replace the roller lever actuator with a different type?

The D4N series allows for head rotation and positioning, but replacing the actuator itself with a different type is generally not recommended and may void the warranty.

What is the operating temperature range?

The Omron D4N-4120 operates reliably within a temperature range of -30°C to 70°C (-22°F to 158°F).

How often should I perform maintenance on this switch?

Regular visual inspection is recommended. Specific maintenance intervals depend on the operating environment and duty cycle, but typically, cleaning and checking for physical integrity are sufficient for most applications.

Are the gold-clad contacts suitable for high-power switching?

Gold-clad contacts are primarily used for their high reliability in low-power or low-voltage applications. For high-power switching, ensure the 10A continuous rating is not exceeded and consider potential wear over time.

Troubleshooting

Switch not triggering consistently.

Check that the actuator lever is properly aligned and that the object is making firm contact. Verify mounting is secure and there is no obstruction.

No continuity or signal when switch is actuated.

Verify wiring connections are secure and correct for the NC/NO contacts. Ensure the switch has not exceeded its mechanical or electrical lifespan. Check for physical damage to the internal contacts (requires expert inspection).

Switch fails to return to its normal state.

Ensure the actuator is fully released and not obstructed. Check for mechanical binding or damage to the spring return mechanism within the switch.

Environmental ingress (water/dust).

Inspect the M20 conduit seal and cable entry. Ensure the switch housing is intact. Re-seal or replace if damage is found.

Pros and Cons

Pros

  • High contact reliability with gold-clad contacts.
  • Long mechanical life (15,000,000 cycles).
  • Durable construction with IP67 environmental protection.
  • Lead-free, cadmium-free, and hexavalent chrome-free for environmental compliance.
  • Versatile 1NC/1NO contact configuration.

Cons

  • Fixed conduit size (M20) may limit some installation scenarios.
  • Resin roller lever may not be suitable for extremely abrasive environments.
  • Requires specific electrical knowledge for proper wiring.
  • Head positioning is limited to four locations.

Setup, Compatibility & Care

Setup:

  1. Mounting: Securely mount the switch using appropriate hardware, ensuring the actuator lever aligns with the intended actuation point.
  2. Wiring: Connect the electrical wires to the screw terminals, observing proper polarity and connection types for the 1NC and 1NO contacts. Ensure the M20 conduit is properly sealed.
  3. Actuation Adjustment: If necessary, adjust the mounting position to ensure the roller lever is actuated by the target object at the desired point.

Compatibility:

The D4N-4120 is designed for general industrial control circuits. Ensure voltage and current ratings are compatible with your control system. The M20 conduit offers broad compatibility with standard industrial cable glands.

Care:

  • Periodically inspect the switch and actuator for any signs of physical damage or wear.
  • Keep the area around the switch clean to prevent excessive dust or debris buildup that could interfere with the actuator.
  • While IP67 rated, avoid direct high-pressure washing on the switch body. Use a damp cloth for cleaning if necessary.