Sennheiser e935 - Cardioid Dynamic Vocal Microphone

This dynamic microphone is best described as an optimised E835. It features a wider frequency rang...

Best current price£86.56from eBay

All Offers

4 offers from £86.56 - £279.00

View price history by clicking the chart icon.

eBaySennheiser E 835-S Dynamic Cardioid Vocal Microphone with Switch
Free delivery in 1–3 days
£86.56
Visit shop
Scan ComputersSennheiser E935 Cardioid Dynamic Vocal Microphone 009421
Free delivery in 1–3 days
£148.00
Visit shop

Used Offer

1 offer from £39.95

View price history by clicking the chart icon.

eBaySENNHEISER E835 HANDHELD CARDIOID DYNAMIC MICROPHONE INC: CLIP & CABLE
Free delivery in 1–3 days
£39.95
Visit shop

Product Information

Full details

The Sennheiser e935 is a dynamic vocal microphone designed for live performances, offering an optimized E835 experience. Its key benefit is superior vocal isolation and noise rejection, ensuring clear sound even in noisy environments. A crucial caveat is its design for Japanese voltage (90-110 V) and plug types (A or B), requiring a voltage transformer for use elsewhere. This guide provides comprehensive information on its features, usage, and care.

All features

Model Part Numbere935
BrandSennheiser

Extended Product Information

FAQs

Do I need a voltage transformer for this microphone?

Yes, the Sennheiser e935 is designed for Japanese voltage (90-110 V). If you are in a region with a different voltage, a voltage transformer is mandatory to prevent damage. A plug adapter alone is not sufficient.

What type of pickup pattern does the e935 have?

The e935 features a cardioid pickup pattern, which means it primarily captures sound from the front while rejecting sound from the sides and rear.

How does the shock mount system benefit me?

The advanced built-in shock mount system isolates the microphone capsule from handling noise and vibrations, preventing these disturbances from being picked up and transmitted through the audio signal, ensuring smoother live performances.

Can this microphone be used for instruments as well as vocals?

While optimized for vocals, the e935's frequency response and durability allow it to be used for instruments, particularly those requiring clear, direct sound reproduction like guitar amps or drums. However, its cardioid pattern is best suited for isolating a specific source.

What is the frequency response range of the e935?

The frequency response range of the Sennheiser e935 is from 40 to 18,000 Hertz.

Is this microphone suitable for home studio recording?

Yes, the e935 can be used for home studio recording, especially for vocals where isolation from room noise is desired. Its dynamic nature makes it less sensitive to room acoustics than condenser microphones.

What is the difference between the e935 and the E835?

The e935 is described as an optimized E835, featuring a wider frequency range (40-18,000 Hz compared to E835's typical range) for more detailed capture.

Troubleshooting

No sound output

Ensure the XLR cable is securely connected to both the microphone and the audio interface/mixer. Check that phantom power is OFF (dynamic microphones do not require phantom power). Verify that the input channel on the mixer is active and at an appropriate gain level.

Excessive handling noise or vibration

Ensure the microphone is held firmly but not excessively, allowing the internal shock mount to function. Avoid tapping or banging the microphone body. Check for any loose connections or mounting hardware if using a stand.

Poor vocal clarity or muffled sound

Adjust microphone placement closer to or further from the vocalist's mouth. Ensure the cardioid pattern is directed towards the sound source and away from potential noise sources. Check EQ settings on the mixer.

Microphone buzz or hum

Try using a different XLR cable. Ensure the audio interface or mixer is properly grounded. Test the microphone with a different input channel or mixer to rule out equipment issues.

Pros and Cons

Pros

  • Excellent vocal isolation due to the cardioid pattern.
  • Handles high sound pressure levels effectively.
  • Reduces unwanted noise with its built-in shockmount.
  • Durable design for consistent live use.
  • Clear and present vocal reproduction.

Cons

  • Requires a voltage transformer for use outside of Japan (90-110 V).
  • A simple plug adapter is insufficient and can cause damage.
  • Cardioid pattern may pick up excessive stage noise if not managed.
  • Not ideal for capturing ambient room sound.

Setup, Compatibility & Care

Setup: Connect the microphone to a compatible audio interface or mixing console using an XLR cable. For optimal performance, ensure the microphone is positioned directly in front of the vocalist.

Compatibility: This microphone is designed for Japanese voltage specifications (90-110 V) and uses Japanese plug types (Type A or B). A voltage transformer is required for use in regions with different voltage systems. Failure to use a transformer may damage the microphone. A simple plug adapter will not suffice.

Care:

  1. Cleaning: Gently wipe the exterior with a soft, dry cloth. Avoid using liquids or abrasive cleaners.
  2. Storage: Store the microphone in its protective case when not in use to prevent dust and damage.
  3. Handling: Avoid dropping the microphone and handle it with care to preserve its internal components and shock mount system.

Price History

DatePrice
Visit shop