Phoenix Contact Timer Relay - PLC-TR-1T - 2910141


Best current price£60.16from Tameson UK
Best offers
Shopping.co.uk recommended and popular offers
Phoenix Contact Multi-Function Timer Relay Plc-Tr-1T - 2910141
Visit shop

Best current price£60.16from Tameson UK
Shopping.co.uk recommended and popular offers
Phoenix Contact Multi-Function Timer Relay Plc-Tr-1T - 2910141
Visit shop1 offer from £60.16
View price history by clicking the chart icon.
This Phoenix Contact 2910141 Timer Relay is designed for industrial automation and control systems requiring precise timing functions. Its key benefit is the ultra-narrow design and multi-functionality, allowing for versatile application in space-constrained environments. A potential caveat is its specific operating voltage requirement. It offers four distinct timing functions, adjustable time ranges, and a single changeover contact, all within a compact form factor with push-in connection terminals.
| Series | PLC-TR-1T |
|---|---|
| Model Part Number | 2910141 |
| Brand | Phoenix Contact |
The specific four functions are typically On-Delay, Off-Delay, Interval, and One-Shot (or Monostable), though exact nomenclature may vary. Refer to the product manual for precise definitions.
The maximum adjustable time range is 300 minutes, which is equivalent to 18,000 seconds.
No, this relay is designed to operate specifically with a DC power supply in the range of 19.2V to 30V.
The single changeover contact (SPDT) is rated for a maximum of 6A.
The time delay is set using the integrated rotary switches or potentiometers on the front of the unit, typically allowing selection of the time range and then a precise setting within that range.
The relay has an operating temperature range of -20 to 65 °C, but it is designed for industrial control cabinet environments and is not inherently weatherproof. Proper enclosure is recommended for protection against environmental factors.
The relay has an ultra-narrow width of 6.2 mm.
Verify the DC power supply voltage is within the 19.2-30V range and correctly connected to the power input terminals.
Double-check the selected timing function and the adjusted time range settings. Ensure the input signal is correctly applied.
Confirm that the relay is powered and has received a valid input signal. Check if the load connected to the output is within the 6A rating.
Ensure wires are fully inserted into the push-in terminals. Release and re-insert wires to guarantee a secure connection.
Setup:
Compatibility:
Care: