Interface Relay Module - Finder 4C Series


Best current price£17.10from Tameson UK
Best offers
Shopping.co.uk recommended and popular offers
Finder Interface Relay Module 24Vac 8A Dual Co With Led - 4C.02.8.024.0060
Visit shop

Best current price£17.10from Tameson UK
Shopping.co.uk recommended and popular offers
Finder Interface Relay Module 24Vac 8A Dual Co With Led - 4C.02.8.024.0060
Visit shop1 offer from £17.10
View price history by clicking the chart icon.
This Finder 4C Series Interface Relay Module is designed for industrial control systems requiring reliable switching of AC loads. It offers a compact, DIN-rail mountable solution with screw terminals for secure connections and dual changeover contacts. While it provides robust performance, users should be aware of its specific 24VAC coil voltage requirement, which might necessitate a dedicated control transformer.
| Series | 4C Series |
|---|---|
| Model Part Number | 4C.02.8.024.0060SPA |
| Brand | Finder |
This Finder 4C Series module features two independent changeover (DPDT) contacts.
Each contact is rated for a maximum of 8 Amperes at 250 Volts AC.
The coil requires a control voltage of 24 Volts AC (50Hz or 60Hz).
The relay module is designed for quick and easy mounting onto a standard 35mm DIN rail.
Yes, this is a complete assembly that includes the relay base, relay unit, module, and retaining clip.
The LED serves as a visual indicator for the status of the relay coil; it typically lights up when the coil is energized.
This relay is designed for AC loads. Using it with DC loads may require specific considerations or additional circuitry and is not its intended application.
The module has an IP20 rating, meaning it is protected against solid objects larger than 12.5mm but has no protection against water. It is suitable for indoor, dry environments within control panels.
Verify that the control voltage is indeed 24VAC and is correctly connected to the coil terminals (A1, A2). Check the control circuit fuse or breaker. Ensure the LED indicator is functioning.
Ensure the control voltage supply has been removed or switched off. Check for any short circuits in the control wiring. Verify the varistor is not causing a permanent short.
Confirm the control coil is energized (check LED). Verify the load wiring is correctly connected to the common and the appropriate normally open (NO) or normally closed (NC) contact terminals. Ensure the load current does not exceed the 8A rating.
Check the 24VAC supply to the coil. Ensure the coil terminals are properly connected. If the coil voltage is correct and the LED still does not light, the relay unit may be faulty.
Ensure the module is within its operating temperature range (-40°C to +70°C). Check that the load current does not exceed the 8A rating. Verify adequate ventilation within the control panel.