The ABB System pro M compact S200 miniature circuit breaker (2CDS251001R0255) is a high-performance safety device designed for professionals and homeowners seeking reliable overload and short-circuit protection in residential, commercial, and industrial electrical systems. Featuring a dual-action thermal and electromechanic tripping mechanism, it ensures precise power management and safety across diverse applications; however, it requires installation by a qualified electrician to ensure adherence to local electrical codes and safety standards.
| Series | System pro M compact S200 |
|---|---|
| Model Part Number | 2CDS251001R0255 |
| Brand | ABB |
Yes, but ensure the 25A rating is appropriate for your specific circuit load. Lighting circuits often use lower amperages, so verify your electrical design.
The breaker itself should be housed within a properly rated, ingress-protected (IP) electrical enclosure to prevent moisture contact.
It refers to the tripping characteristic. B-curve breakers are designed for circuits with low surge currents, typically used for resistive loads.
Warranty terms vary by region and distributor; please refer to your purchase documentation or contact ABB directly with your MPN 2CDS251001R0255.
The unit weighs approximately 125 grams.
The S200 series is primarily designed for AC voltages. Consult the technical datasheet for specific DC application constraints.
Indicates a persistent short circuit or ground fault. Disconnect all loads on the circuit and check for damaged wiring or faulty appliances before resetting.
Check for loose terminal connections causing resistance or verify if the circuit is continuously running near its 25A capacity.
The internal mechanism may be locked or damaged. If the circuit is verified to be clear of faults, the unit may require replacement.
Installation must always be performed by a licensed professional in accordance with local building codes. The unit mounts onto a standard DIN rail. When installing, ensure that the cables are properly seated in the patented twin terminals and tightened to the manufacturer's torque specifications. The device is designed to be maintenance-free under normal operating conditions. Periodically, however, verify that the terminals remain tight and that there is no dust or debris accumulation inside the distribution board. Always check that the current rating (25A) and the tripping characteristic match the specific requirements of the load being protected.