External Air Admittance Valve - Plumbright - AX110 White


Currently unavailable


Currently unavailable
The Plumbright External Air Admittance Valve (AX110 White) is designed for plumbers and homeowners needing to ensure proper ventilation in sanitary pipework systems. Its key benefit is preventing foul gases from entering a building while allowing free air entry, resolving issues caused by negative pressure in drains. A potential caveat is its external installation requirement, which may be less aesthetically desirable for some.
| Model Part Number | AX110 White |
|---|---|
| Brand | Plumbright |
An External Air Admittance Valve (AAV) is a fitting installed in a drainage system that allows air to enter the pipes but prevents foul sewer gases from escaping into a building. It helps maintain correct system pressure.
External AAVs are installed on the outside of a building, removing the need for traditional vents through the roof. This can be beneficial for aesthetics and in situations where routing a vent pipe through the roof is difficult or impossible.
Signs include slow draining, gurgling sounds from pipes or fixtures, and water being siphoned out of toilet or basin traps. Building regulations often mandate their use in specific circumstances.
The AX110 White is designed for 110 mm diameter drainage pipes and features a push-fit connection.
Installation requires basic plumbing knowledge and the use of solvent cement. If you are not comfortable with plumbing work or solvent welding, it is recommended to hire a qualified professional.
It is advisable to check the exterior of the valve periodically for any obstructions and clean it with a damp cloth. Ensure it remains unobstructed for proper airflow.
PVC-C (Chlorinated Polyvinyl Chloride) is a variation of PVC-U (Unplasticized Polyvinyl Chloride) that has undergone an additional chlorination process. This makes PVC-C more resistant to heat and provides superior fire performance compared to standard PVC-U.
Check that the air admittance valve is installed correctly in an upright position and is not blocked externally. Ensure the pipework connection is secure.
Verify that the air admittance valve is functioning correctly and opening to allow air entry during discharge. Ensure it is rated for the specific discharge volume.
Confirm the air admittance valve is not the source of the odor; it only allows air entry. Check the main drainage system, seals, and connections for leaks or blockages that might be allowing gases to escape elsewhere.
Inspect the valve for cracks or damage. If damage is found, it will need to be replaced. Ensure solvent weld joints were made correctly.
Setup:
Compatibility:
Care: