Eaton 9PX uninterruptible power supply (UPS) - 9PX3000IRTNBS

The Eaton 9PX UPS provides energy-efficient power protection for small & medium Datacentres, IT ro...

Best current price£1,514.57from PCHUB.UK

All Offers

17 offers from £1,514.57 - £2,851.12

View price history by clicking the chart icon.

PCHUB.UKEaton 9Px2200irt2ubs Uninterruptible Power Supply (Ups) Double-Convers
Free delivery in 1–3 days
£1,514.57
Visit shop
GamingKitEaton 9Px2200irt2ubs Uninterruptible Power Supply (Ups) Double-Convers
Free delivery in 1–3 days
£1,817.48
Visit shop
eBayEaton Double Conversion Online Ups 2.20 Kva/2.20 Kw 2U Rack/Tower 230 V Ac Input
Free delivery in 1–3 days
£1,947.15
Visit shop
Laptops Direct (BID)Eaton 9Px - Netpack - Ups (Rack-Mountable / External) - Ac 200/208/220/230/240 V - 3000 Watt - 3000 Va - 1-Phase - 9 Ah Black,Silver, Laptops Direct - 9PX3000IRTNBS
£6.95 delivery
£2,803.97
Visit shop
Servers Direct (BID)Eaton Black,Silver 9Px - Netpack - Ups (Rack-Mountable / External) - Ac 200/208/220/230/240 V - 3000 Watt - 3000 Va - 1-Phase - 9 Ah
£6.95 delivery
£2,803.97
Visit shop

Product Information

Full details

This guide helps IT and facility managers understand and effectively use the Eaton 9PX UPS for their small to medium datacenters and IT rooms. The 9PX provides reliable, energy-efficient power protection with its double-conversion design, ensuring your critical equipment stays online during outages. While offering robust protection, users should be aware of the 3-minute typical backup time at full load, which might require additional planning for extended power failures. This guide covers key features, setup, usage, and troubleshooting to help you maximize the benefits of your Eaton 9PX UPS.

All features

Model Part Number9PX3000IRTNBS
BrandEaton

Extended Product Information

FAQs

How long will the UPS provide backup power?

The typical backup time at full load is approximately 3 minutes. The actual backup time depends on the load connected to the UPS.

How do I replace the battery?

Refer to the user manual for battery replacement instructions. It usually involves opening the unit and swapping the battery. Always follow safety precautions.

Can I connect more devices than the number of outlets?

No, you should not connect more devices than the available outlets, as it could overload the UPS. The 9PX has 10 AC outlets.

What kind of power cord does the UPS use?

The UPS uses a C20 coupler for input power.

How do I monitor the UPS remotely?

Connect the UPS to your network using an Ethernet cable. Use the included network card to access the monitoring and management features through a web interface or a network management system.

What is the warranty period?

Warranty information is not available in the product data, consult the product documentation for warranty details.

How often should I test the UPS battery?

It is recommended to perform a self-test every 3-6 months to ensure the battery is functioning correctly. The UPS may also perform automatic battery tests.

Troubleshooting

UPS not turning on.

Check the power connection and ensure the UPS is plugged into a working outlet. Verify the power switch is in the 'on' position.

UPS beeping continuously.

The UPS is likely in battery mode due to a power outage or voltage fluctuation. Check the incoming power and the battery status.

UPS displaying an error message.

Consult the user manual for specific error codes and troubleshooting steps. Common errors include overload, battery failure, or internal faults.

Battery backup time is shorter than expected.

The battery may be nearing the end of its life, or the connected load may be too high. Consider replacing the battery or reducing the load.

Pros and Cons

Pros

  • Provides reliable power protection against outages and fluctuations.
  • Offers high efficiency, reducing energy costs.
  • Features a unity power factor for increased power delivery.
  • Flexible rackmount/tower design.
  • Includes a network card for remote monitoring.

Cons

  • Limited backup time at full load (approximately 3 minutes).
  • Requires professional installation for rackmount configurations.
  • Battery replacement needed every few years.
  • Can be heavy, requiring careful handling.

Setup, Compatibility & Care

  1. Unpacking and Inspection: Carefully unpack the UPS and inspect it for any shipping damage. Ensure all components are present.
  2. Rackmount Installation: If rackmounting, use the provided rackmount kit. Follow the instructions for secure installation in a standard 19-inch rack.
  3. Tower Installation: For tower configurations, place the UPS on a stable, level surface.
  4. Connecting Devices: Connect your critical equipment to the output outlets on the back of the UPS.
  5. Input Power Connection: Plug the UPS into a dedicated power outlet using the provided power cord. Use a C20 coupler for the input.
  6. Network Configuration: Connect the network cable to the UPS's network port for remote monitoring and management.
  7. Initial Startup: Power on the UPS and configure the settings through the LCD display, such as input voltage and output voltage.

Compatibility:

The Eaton 9PX UPS is compatible with a wide range of devices, including servers, network equipment, and storage devices. Ensure that the total power consumption of your connected devices does not exceed the UPS's output capacity of 3000W / 3000VA.

Care:

  • Keep the UPS in a clean, dry environment.
  • Regularly check the battery status via the LCD display or the network management interface.
  • Conduct periodic self-tests to ensure the UPS is functioning correctly.
  • Replace the battery every 3-5 years, depending on usage and environmental conditions.
  • Do not block the ventilation openings on the UPS.

Similar items

Price History

DatePrice
Visit shop