ABB Ground fault block - DDA 200 A - 40A - 30mA - Type A

This earth fault block from ABB Haf's DDA200 series has a total of 4 poles. The ground fault block...

Best current price£67.57from eBay

All Offers

3 offers from £67.57 - £266.89

View price history by clicking the chart icon.

eBayABB 2CSB204101R3400 DDA204 A-40/0.3 RCD Block
Free delivery in 1–3 days
£67.57
Visit shop
Tameson UKAbb System Pro M Compact Ground Fault Block - 2Csb204101r1250
Free delivery in 1–3 days
£245.26
Visit shop

Used Offers

2 offers from £50.03 - £50.22

View price history by clicking the chart icon.

eBayAbb 2Csb202101R3250 Dda202 A-25/0.3
Free delivery in 1–3 days
£50.03
Visit shop

Product Information

Full details

This ABB DDA204A-40/0.03 ground fault block is designed for electrical systems requiring reliable protection against earth faults. It is ideal for installers and electricians needing to ensure safety in residential, commercial, and industrial settings. Its primary benefit is providing sensitive detection of residual currents with a 30mA trip sensitivity, safeguarding against electric shock and fire hazards. A key consideration is its Type A classification, meaning it detects AC and pulsating DC residual currents.

All features

SeriesDDA 200 A
Model Part Number2CSB204101R1400 - DDA204A-40/0.03
BrandABB

Extended Product Information

FAQs

What is the main purpose of this ground fault block?

Its main purpose is to protect electrical circuits and users from the dangers of earth faults by rapidly disconnecting power when a residual current is detected.

What does 'Type A' classification mean for this module?

Type A classification means this residual current device can detect both AC and pulsating DC residual currents, offering more comprehensive protection than Type AC devices.

What is the maximum current this module can handle?

This module has a rated current of 40A, meaning it is suitable for circuits with a maximum continuous load of 40 Amperes.

Can I use this module with any circuit breaker?

This module is designed to be used with ABB S200 series circuit breakers that have an identical or lower rated current than the module's 40A rating.

What is the rated fault current, and why is 30mA important?

The rated fault current is 30mA (0.03A). This sensitivity is considered the threshold for preventing serious electric shock to people, making it suitable for personnel protection in many applications.

How often should I test this device?

It is recommended to test residual current devices periodically, typically monthly, using the integrated test button if available, or a dedicated RCD tester. Consult your local electrical regulations for specific testing intervals.

What voltage systems is this module designed for?

This module is designed for nominal voltages ranging from 230V to 400V AC.

Troubleshooting

Module trips immediately upon power restoration

This indicates a persistent earth fault in the protected circuit or connected appliances. Check all wiring for correct connections and insulation. Test appliances individually to identify the faulty one.

Module does not trip when an earth fault is suspected

Ensure the module is correctly wired. Perform a test using the integrated test button (if applicable) or a dedicated RCD tester. If the test fails, the module may be faulty and require replacement by a qualified electrician.

Overheating or unusual noises

Immediately disconnect power to the circuit. Inspect the module and connections for signs of damage or loose connections. Contact a qualified electrician for inspection and potential replacement.

Pros and Cons

Pros

  • Provides essential protection against electric shock and fire due to earth faults.
  • Type A classification offers superior detection capabilities for common fault types.
  • Robust design suitable for various environments.
  • Easy integration with existing ABB S200 systems.
  • Clear indication of key electrical specifications on the unit.

Cons

  • Requires specific compatibility with S200 circuit breakers for optimal performance.
  • Type A classification does not detect smooth DC residual currents.
  • Requires knowledgeable personnel for correct installation and wiring.
  • Rated voltage range might not cover all global electrical standards without appropriate transformers.

Setup, Compatibility & Care

Setup: This residual current device module is designed for DIN rail mounting. Ensure the main power is disconnected before installation. Connect the incoming live and neutral conductors to the appropriate terminals on the module, and the outgoing conductors to the circuit breaker or downstream loads. It is intended to be used in conjunction with ABB S200 series circuit breakers that have a rated current equal to or lower than the 40A rating of this module.

Compatibility: The DDA204A-40/0.03 is compatible with ABB S200 circuit breakers. It operates within a nominal voltage range of 230V to 400V AC. Ensure your electrical system's voltage aligns with these specifications. It is classified as Type A, suitable for detecting AC and pulsating DC residual currents.

Care: To maintain optimal performance, periodic testing is recommended. Consult local electrical codes and regulations for the required testing frequency. Visually inspect the module for any signs of damage or overheating. Keep the area around the module clean and free from dust and debris. No user-serviceable parts are inside; any repairs should be performed by a qualified electrician.