IG Lintels L1/S100 Standard Structural Steel Lintel - 900mm
Our L1/S100 standard cavity lintels provide ideal structural support for cavity wall openings. The...Our L1/S100 standard cavity lintels provide ideal structural support for cavity wall openings. The lintels are suitable for cavity widths of between 95-110mm. Its top hat' profile offers greater integral strength and improved thermal performance. The cavity lintels all arrive with perforations, inbuilt on the inner flange to offer a plaster key for additional work. This robust and reliable solution is designed to accommodate cavity widths of 90-105mm, ensuring stability and endurance in various building applications. Crafted for standard load-bearing applications, this lintel offers a minimum end bearing of 150mm on each side of the opening, ensuring secure installation and enhanced structural integrity.
This guide is for builders and construction professionals using IG Lintels L1/S100 structural steel lintels. These lintels offer robust support for cavity wall openings with a cavity width between 95-110mm, improving structural integrity and thermal performance. Keep in mind that proper installation, including the required 150mm end bearing, is crucial for optimal performance.
All features
Colour
Silver
Model Part Number
5023545101983
Brand
IG Lintels
Extended Product Information
FAQs
What is the purpose of the perforations on the inner flange?
The perforations provide a key for plaster, allowing for a better bond and finish.
What is the minimum end bearing required?
A minimum end bearing of 150mm on each side of the opening is required.
What cavity widths are these lintels suitable for?
These lintels are suitable for cavity widths between 95-110mm.
What type of applications are these lintels designed for?
These lintels are designed for standard load-bearing applications in cavity walls.
How do I ensure the lintel is installed correctly?
Follow standard building practices for lintel installation and ensure the lintel is level and properly supported, with the required end bearing.
Can these lintels be used in all types of buildings?
These lintels are suitable for a wide range of buildings but are specifically designed for standard load-bearing applications within the specified cavity width range.
What should I do if the lintel is damaged during transport or installation?
If the lintel is damaged, assess the extent of the damage. For minor damage, touch up the protective coating. For significant damage, consider replacing the lintel or consulting a structural engineer.
Troubleshooting
Lintel appears to be sagging or bowing after installation.
Check the end bearing to ensure it meets the minimum requirement of 150mm on each side. If the bearing is insufficient, the lintel may not be adequately supported. Check for any damage or stress on the lintel.
Difficulties in aligning the lintel during installation.
Ensure the opening is accurately measured and prepared before installing the lintel. Use appropriate shims and supports to level the lintel during the installation process.
Rust or corrosion is visible on the lintel.
Inspect the protective coating for any damage. Address any areas where the coating is compromised and apply a suitable anti-corrosion treatment or coating if necessary.
Pros and Cons
Pros
Provides reliable structural support for cavity wall openings.
Offers improved thermal performance compared to some alternatives.
Features a plaster key for ease of use.
Designed for standard load-bearing applications, ensuring versatility.
Offers robust and durable construction for long-lasting performance.
Cons
Requires precise measurement and installation to ensure proper load distribution.
Specific to cavity widths of 95-110mm, limiting its use in other applications.
Steel construction can be susceptible to corrosion if not properly protected.
May require specialist equipment for handling and installation due to its weight.
Thermal performance is improved, but not a complete thermal solution on its own.
Setup, Compatibility & Care
Preparation: Ensure the cavity width is within the 95-110mm range.
Positioning: Place the lintel above the opening, ensuring a minimum end bearing of 150mm on each side.
Installation: Follow standard building practices for lintel installation, ensuring it is level and properly supported.
Compatibility: Compatible with standard cavity wall construction methods and materials.
Care: Protect the lintel from the weather during storage and installation. Any damage to the protective coating should be addressed promptly.