Scan Sm7501 Twin Half Mask Respirator

The Scan Twin Half Mask Respirator offers maximum protection and comfort in various environments. ...

Best current price£11.64from Power Tools Direct

All Offers

4 offers from £11.64 - £15.00

View price history by clicking the chart icon.

Power Tools DirectScan Sm7501 Twin Half Mask Respirator No Filters
£5.95 delivery
£11.64
Visit shop
Blueperry agriculture (UK)Scan Twin Half Mask Respirator Sm7501
Free delivery in 1–3 days
£13.60
Visit shop
B&QB&Q - Sm7501 Twin Half Mask Respirator No Filters Scapperespmo
Free delivery in 1–3 days
£14.96
Visit shop
www.rhino-build.comScan Twin Half-Mask Respirator – No Filters
Free delivery in 1–3 days
£15.00
Visit shop

Product Information

Full details

The Scan Sm7501 Twin Half Mask Respirator is designed for professionals needing reliable respiratory protection against dust, fumes, vapors, and gases. Its key benefit is the comfortable, secure seal and compatibility with a wide range of filters. A crucial caveat is that filters are sold separately and must be chosen based on the specific hazard.

All features

BrandScan

Extended Product Information

FAQs

What type of filters are compatible with the Scan Sm7501?

The Scan Sm7501 Twin Half Mask Respirator uses Scan bayonet connectors, making it compatible with the full range of Scan particle and gas cartridges.

Are filters included with the respirator?

No, filters are sold separately. You must select and purchase the appropriate filters based on the specific hazards in your work environment.

How often should I clean the respirator?

The respirator should be cleaned after each use with mild soap and water. Ensure it is completely dry before storing.

Can I wear this respirator if I have facial hair?

Wearing a half-mask respirator with significant facial hair (beard, stubble) can prevent a proper seal, compromising protection. It is recommended to be clean-shaven where the mask contacts the skin.

What is the certification for this respirator?

The Scan Sm7501 Twin Half Mask Respirator is certified to EN140:1998 standards.

How do I perform a user seal check?

Cover the filter inlets with your hands and inhale gently. The mask should pull slightly towards your face and remain collapsed. If you detect any air leakage, readjust the mask and straps and repeat the check.

Can this respirator be used for protection against all gases and vapors?

The level of protection depends on the specific filter cartridge used. You must select a cartridge specifically designed for the type of gas or vapor you are exposed to and ensure its capacity is not exceeded.

Troubleshooting

Mask does not seal properly

Adjust the head straps for a tighter fit. Ensure facial hair is not interfering with the seal. Perform a user seal check to identify any leaks.

Difficulty breathing through the mask

Check if the filters are clogged or if the wrong type of filter is attached. Ensure the exhalation valve is not obstructed. Consider if a higher airflow filter is needed.

Fogging inside the mask

Ensure the mask is fitted correctly. Reduce physical exertion if possible, or ensure the exhalation valve is functioning properly to vent moisture.

Components appear damaged or worn

Inspect the facepiece, straps, and filter connections for cracks or tears. Replace any damaged parts immediately. Do not use the respirator if any component is compromised.

Pros and Cons

Pros

  • Provides robust protection against various airborne hazards.
  • Comfortable for extended use due to soft silicone and efficient exhalation valve.
  • Customizable protection with a wide range of compatible filters.
  • Secure and adjustable fit for different users.
  • Durable construction for demanding environments.

Cons

  • Filters are not included and must be purchased separately.
  • Requires proper fit testing to ensure effectiveness.
  • May not be suitable for extremely high concentrations of certain gases without specific cartridge selection.
  • Requires regular maintenance and filter replacement.

Setup, Compatibility & Care

Setup:

  1. Ensure the respirator and chosen filters are clean and undamaged.
  2. Attach the selected Scan particle or gas filters to the bayonet connectors on the respirator, ensuring they click securely into place.
  3. Adjust the elastic head straps for a snug, comfortable fit. The mask should create a seal around the nose and mouth without being overly tight.
  4. Perform a user seal check before each use.

Compatibility:

  • This respirator is compatible with the full range of Scan bayonet fit particle and gas cartridges.
  • Always select filters appropriate for the specific hazard and concentration level present in the working environment.

Care:

  • Clean the respirator after each use with mild soap and water. Do not use solvents or harsh detergents.
  • Allow the respirator to air dry completely before storing.
  • Store the respirator in a clean, dry place, away from direct sunlight and chemicals.
  • Inspect the facepiece and straps regularly for signs of wear or damage. Replace any damaged parts immediately.

Price History

DatePrice
Visit shop