Portwest P306 FFP3 Ultimate Valved Reusable Respirator (Pk5)

Experience ultimate comfort and protection with our FFP3 valved respirator. With low breathing res...

Best current price£16.00from The PPE Online Shop

All Offers

3 offers from £16.00 - £28.14

View price history by clicking the chart icon.

The PPE Online ShopPortwest White Ffp3 Ultimate Valved Reusable Respirator (Pk5)
Free delivery in 1–3 days
£16.00
Visit shop
DIY Refurb UKWorkwear Nation Ltd Portwest P306 Ffp3 Ultimate Valved Reusable Respirator (Pk5)
Free delivery in 1–3 days
£19.12
Visit shop
eBayPortwest P306 FFP3 Ultimate Valved Reusable Respirator (Pk5) - Comfortable Fit
Free delivery in 1–3 days
£28.14
Visit shop

Product Information

Full details

This guide is for professionals requiring high-level respiratory protection in demanding environments. The Portwest P306 FFP3 respirator offers superior comfort and filtration with low breathing resistance, an ergonomic fit, and a high-performance exhalation valve. A key caveat is its classification as reusable for *more than one working shift*, meaning proper care and maintenance are essential for continued effectiveness.

All features

BrandPortwest

Extended Product Information

FAQs

What does FFP3 R D certification mean?

FFP3 indicates the highest level of filtration for respirators in Europe. 'R' means it is reusable for more than one working shift, and 'D' signifies it has passed the optional Dolomite clogging test, meaning it offers better breathing comfort and a longer filter life in dusty environments.

How do I know if the respirator fits properly?

Perform a user seal check. Cover the respirator with your hands and exhale gently. You should not feel any air escaping around the edges. The foam gasket should create a continuous seal against your skin.

Can I wash this respirator?

No, this respirator is not designed to be washed. You can clean the internal foam gasket and exhalation valve with a damp cloth. Excessive moisture or washing will damage the filter material and compromise its effectiveness.

How long can I reuse the Portwest P306 respirator?

The 'R' certification means it can be reused for more than one working shift. However, it must be replaced if it becomes damaged, the filter is clogged, breathing becomes difficult, or it no longer provides a good seal.

Is this respirator suitable for welding fumes?

This FFP3 respirator primarily protects against particulates (dust, mist, aerosols). It is not designed to filter gases or vapors, so it may not be suitable for all welding fumes. Consult specific safety data sheets for the materials being welded.

What is the advantage of the Dolomite clogging test?

Passing the Dolomite test (marked with 'D') means the respirator performs better in environments with heavy dust. It indicates that the filter is less likely to clog quickly, providing more comfortable breathing and extending the filter's usable life.

Is this respirator magnetic?

No, the Portwest P306 is 100% metal-free and non-magnetic, meaning it is free from nickel and ferrous materials. This makes it suitable for use in environments where metal detection is a requirement.

Troubleshooting

Mask feels loose or air leaks detected during seal check.

Readjust the wide elastic head straps for a tighter fit. Ensure the foam gasket is correctly positioned and making full contact with the skin. Try repositioning the respirator on your face.

Difficulty breathing through the respirator.

Check if the exhalation valve is clear and functioning correctly. Ensure the filter is not clogged. If the respirator has been used extensively or exposed to heavy particulate matter, it may need replacement.

Exhalation valve seems to be leaking air.

Inspect the exhalation valve for damage or debris. Ensure it is properly seated. If damaged, the respirator should be replaced.

Mask becomes damp or uncomfortable inside.

This can occur during heavy exertion or in humid conditions. The high-performance exhalation valve helps mitigate this. Take short breaks if necessary. Ensure the respirator is not already saturated and needs replacement.

Pros and Cons

Pros

  • Excellent filtration performance (FFP3 R D).
  • High comfort due to low breathing resistance and exhalation valve.
  • Secure and adaptive fit for various face shapes.
  • Durable and reusable design for cost-effectiveness.
  • Metal-free construction for specific environments.

Cons

  • Requires proper cleaning and maintenance to maintain reusability and effectiveness.
  • May require a fit test to ensure optimal seal.
  • Bulk packaging (Pk5) might not suit individual needs without repackaging.
  • The Dolomite test is optional, so users should verify if their specific model includes it for maximum comfort in dusty conditions.

Setup, Compatibility & Care

Setup:

  1. Inspect the respirator for any damage before use.
  2. Adjust the wide elastic head straps to achieve a snug but comfortable fit. Ensure the straps are not twisted.
  3. Position the respirator on your face, ensuring the foam gasket creates a complete seal around the nose and mouth.
  4. Perform a user seal check by cupping your hands over the respirator and exhaling gently. You should feel no air leakage around the edges. If leakage is detected, readjust the straps and the position of the respirator.

Compatibility:

  • Certified to EN 149 FFP3 R D standards.
  • Suitable for most face shapes due to its ergonomic design and adjustable straps.
  • 100% metal-free, making it compatible with metal-sensitive environments.

Care and Maintenance:

  • Cleaning: Gently wipe the interior foam gasket and exhalation valve with a clean, damp cloth. Avoid using solvents or harsh cleaning agents. The respirator itself is not designed to be washed.
  • Storage: Store in a cool, dry place away from direct sunlight and contaminants when not in use. The retail box aids in maintaining hygiene and presentation.
  • Disposal: While reusable for extended periods, the respirator must be replaced if it becomes damaged, the filter becomes clogged, or breathing resistance increases significantly. Follow local regulations for disposal of used PPE.

Price History

DatePrice
Visit shop