Eaton Auxiliary Contact Block - DILM32-XHI11-S - DILM





Best current price£59.88from eBay
Best offers
Shopping.co.uk recommended and popular offers
eBay£59.88Visit shop DILM 32-XHI11-S AUXILIARY CONTACT BLOCK 6A 1Z+1R ASSEMBLY 101371
Visit shop




Best current price£59.88from eBay
Shopping.co.uk recommended and popular offers
eBay£59.88Visit shop DILM 32-XHI11-S AUXILIARY CONTACT BLOCK 6A 1Z+1R ASSEMBLY 101371
Visit shop4 offers from £59.88 - £110.17
View price history by clicking the chart icon.
1 offer from £13.78
View price history by clicking the chart icon.
This Eaton DILM Auxiliary Contact Block (DILM32-XHI11-S) is designed for industrial applications requiring reliable signaling for motor starters and other control circuits. It offers a straightforward way to add auxiliary contacts to compatible Eaton DILM contactors, enhancing system monitoring and control capabilities. A key benefit is its simple side-mounting design and screw terminal connections, which facilitate quick installation. However, it is important to note that this module only provides 1 normally open and 1 normally closed contact, and may not be suitable for applications requiring multiple contact configurations or different contact types.
| Series | DILM |
|---|---|
| Model Part Number | 101371 DILM32-XHI11-S |
| Brand | Eaton |
Its main purpose is to provide additional signaling contacts (one normally open and one normally closed) for monitoring the state of a compatible Eaton DILM contactor, which can be used for control or safety interlock circuits.
This module has two types of contacts: 1 normally open (N/O) contact and 1 normally closed (N/C) contact. It does not have change-over (C/O) contacts.
The total current rating (Ith) is 16 A. The rated operation current (Ie) at AC-15, 230 V is 6 A. The contact current rating is 4 A AC and 10 A DC.
It is designed for side mounting onto compatible Eaton DILM contactors (DILM17 to DILM38 series).
The module can operate reliably in temperatures ranging from -25°C to +60°C.
No, this auxiliary contact block is specifically designed for use with Eaton DILM series contactors, from DILM17 to DILM38.
No, this specific model (DILM32-XHI11-S) does not include an integrated lamp or visual indicator.
Verify that the main contactor is correctly energized and de-energized. Ensure the auxiliary contact block is properly seated on the contactor. Check wiring connections at the screw terminals for looseness or incorrect placement.
Double-check the wiring against the circuit diagram. Ensure you are using the correct terminals for the normally open and normally closed functions. Confirm the main contactor is properly engaged.
Confirm that the main contactor is from the compatible DILM series (DILM17-DILM38). Ensure no obstructions are present on the contactor or the module's mounting interface.
Setup:
Compatibility:
Care: