Eaton Motor Protection Circuit Breaker - PKZM0 - 286084

Pre-assembled 3-pole motor protection circuit breaker housed in an IP20-rated enclosure, designed ...

Best current price£59.99from eBay

All Offers

13 offers from £59.99 - £199.51

View price history by clicking the chart icon.

eBayEaton 286083 1.6A Motor-Protective Circuit Breaker With Enclosure - PKZM01-1,6-G
Free delivery in 1–3 days
£59.99
Visit shop
Tameson UKEaton Industries Eaton Pkzm01 Motor Protection Circuit Breaker 4-6.3A - 286086
Free delivery in 1–3 days
£84.02
Visit shop
Blueperry agriculture (UK)Eaton Engine Circuit Breaker With Housing Pkzm0125g
Free delivery in 1–3 days
£134.06
Visit shop

Product Information

Full details

This Eaton Motor Protection Circuit Breaker (MPCB) is designed for industrial applications to protect three-phase motors up to 1.5 kW against overloads and short circuits. Its pre-assembled, IP65-rated enclosure simplifies installation, offering robust protection. A key benefit is its adjustable current setting, allowing precise motor matching. However, it lacks an integrated auxiliary switch, requiring external wiring for signaling functions.

All features

SeriesPKZM01
Model Part Number286084
BrandEaton

Extended Product Information

FAQs

What is the maximum motor power this breaker can protect?

This breaker is designed for motor loads up to 1.5 kW at 440V.

Can this breaker be used for single-phase motors?

No, this is a 3-pole motor protection circuit breaker designed specifically for three-phase AC motor loads.

What does the 'IP65' rating mean?

IP65 indicates that the enclosure is dust-tight and protected against water jets from any direction, making it suitable for harsh environments.

How do I adjust the current setting?

The current setting is adjusted using the rotary knob on the front of the breaker, typically calibrated from 1.6 A to 2.5 A.

Does this breaker have an auxiliary contact for remote signaling?

No, this specific model (PKZM01-2,5-G) does not have an integrated auxiliary switch. Auxiliary contacts would need to be added separately if required.

What is the short-circuit breaking capacity?

The rated short-circuit breaking capacity (Icu) is 50 kA at 400 V AC.

Is a manual reset required after a trip?

Yes, after an overload or short-circuit trip, a manual reset using the push-button is required.

Troubleshooting

Breaker trips immediately upon motor startup.

Check if the overload setting (1.6-2.5 A) is too low for the motor's startup current. Increase the setting if the motor's actual full load current is higher. Verify the motor is not jammed or under excessive load.

Breaker trips during normal motor operation.

The overload setting may be too close to the motor's full load current, or the motor may be drawing excessive current due to overheating, voltage imbalance, or mechanical issues. Verify the setting and motor condition.

Breaker does not reset after tripping.

Ensure the cause of the trip (overload or short circuit) has been resolved. Some models require a brief cool-down period after an overload trip. Check for any mechanical obstruction preventing the reset button from engaging.

Motor fails to start, breaker does not trip.

Verify power supply to the breaker is present and correct phase sequence is maintained. Check internal connections and ensure the motor itself is functional. The breaker may have failed internally, though this is rare.

Pros and Cons

Pros

  • Streamlined installation due to pre-assembled enclosure.
  • Adjustable thermal overload protection for precise motor matching.
  • Robust IP65 rating for protection against dust and water ingress.
  • Compact design suitable for various industrial panel layouts.
  • Effective phase failure sensitivity for enhanced motor safety.

Cons

  • No integrated auxiliary switch for remote signaling.
  • Limited to motor loads up to 1.5 kW at 440V.
  • Basic push-button interface, lacks advanced diagnostic features.
  • Requires manual reset after a trip event.

Setup, Compatibility & Care

Setup:

  1. Ensure the power to the circuit is disconnected.
  2. Mount the complete device in its housing onto a suitable DIN rail or panel.
  3. Connect the motor power leads to the main circuit terminals using screw connections. Ensure correct phase rotation.
  4. Set the desired overload current by adjusting the rotary knob to the appropriate value within the 1.6 to 2.5 A range.
  5. Connect the motor control circuit if required (e.g., for remote start/stop if using external relays).

Compatibility:

  • Designed for use with three-phase AC motor loads.
  • Rated for operation up to 440 V (rated operating voltage) and 690 V (maximum voltage rating).
  • Suitable for circuits with a prospective short-circuit current of up to 50 kA at 400 V.

Care:

  • Periodically inspect the enclosure for damage or ingress of contaminants.
  • Ensure all screw terminals remain tight; re-tighten if necessary (typically during scheduled maintenance).
  • Test the push-button operation to ensure the mechanism is functioning freely.
  • The device is maintenance-free regarding its internal components, but the external enclosure should be kept clean.