ABB Switch-Disconnector - E204/100R - 4 Pole 100A

These devices are suitable for commanding loads and they are realized according EN 60947-3 and EN ...

Best current price£66.22from eBay

All Offers

3 offers from £66.22 - £105.01

View price history by clicking the chart icon.

eBayE204/100A 2CDE284001R0100 E200 Modular Disconnector 100A 4P
£13.20 delivery
£66.22
Visit shop
Tameson UKAbb System Pro M Compact Switch-Disconnector - 2Cde284001r0100
Free delivery in 1–3 days
£97.28
Visit shop

Product Information

Full details

The ABB E204/100R is a 4-pole, 100A switch-disconnector designed for commanding loads, suitable for industrial and commercial applications requiring reliable circuit isolation. Its key benefit is fast removal from the busbar without dismantling, streamlining maintenance. A caveat is its IP10 degree of protection, meaning it requires installation within an enclosure for adequate environmental protection. This device adheres to EN 60947-3 and EN 60669-1 standards, offering secure operation with features like captive screws and optional auxiliary contacts.

All features

SeriesE204
Model Part NumberE204/100R
BrandABB

Extended Product Information

FAQs

What is the primary function of the E204/100R?

The E204/100R is a switch-disconnector used to command loads, meaning it can safely switch circuits ON and OFF and disconnect them for maintenance purposes, conforming to relevant safety standards.

Can this switch-disconnector be used for DC circuits?

No, this device is rated for AC voltage only (12V to 400V AC).

How do I ensure unauthorized operation is prevented?

An accessory locking device can be fitted to prevent unauthorized switching operations. This is particularly useful in shared or high-traffic electrical rooms.

What is the significance of the IP10 rating?

An IP10 rating means the device offers protection against solid objects greater than 50mm (like a large hand) but has no protection against water. Therefore, it must be installed within a suitable enclosure to protect it from environmental factors and ensure safety.

How many auxiliary contacts can be added?

You can add up to three S2C-H6R auxiliary contacts to the E204/100R for signaling or interlocking purposes.

What type of screwdriver is needed for the captive screws?

The captive screws are Pozidrive size 2.

What standards does this device comply with?

The E204/100R complies with EN 60947-3 and EN 60669-1 standards.

Troubleshooting

Device does not switch

Verify that the load is not short-circuited and that the voltage supply is within the rated limits (12V-400V AC). Check for any obstructions preventing the switch mechanism from moving. Ensure auxiliary contacts are not preventing operation if installed.

Switch is difficult to operate

Ensure the device is properly seated on the busbar and that mounting screws are not overtightened. Check for any foreign objects obstructing the mechanism. If auxiliary contacts are installed, ensure they are correctly fitted.

Overheating during operation

Confirm that the connected load does not exceed the rated current of 100A. Check the tightness of all electrical connections. Ensure adequate ventilation if the device is installed within an enclosure.

Auxiliary contact not signaling

Verify that the S2C-H6R auxiliary contact is correctly installed and wired according to its manual. Ensure the associated control circuit is functional and powered.

Pros and Cons

Pros

  • Facilitates quick maintenance through fast busbar removal.
  • Robust construction suitable for demanding load commanding applications.
  • Offers flexibility with the option to add auxiliary contacts.
  • Complies with international safety standards (EN 60947-3, EN 60669-1).
  • Secure operation with captive screws and optional locking mechanism.

Cons

  • Limited environmental protection (IP10) requires installation within an enclosure.
  • Requires specific Pozidrive size 2 screwdriver for captive screws.
  • Auxiliary contacts are optional and must be purchased separately.
  • Designed for AC voltage only.

Setup, Compatibility & Care

Setup:

  1. Ensure the power supply is completely disconnected before installation.
  2. Mount the E204/100R onto the busbar system, ensuring secure connection.
  3. If required, install up to three S2C-H6R auxiliary contacts according to their specific instructions.
  4. Connect the main load and supply conductors to the appropriate terminals using suitable torque.
  5. Secure the device using the captive Pozidrive size 2 screws.
  6. If environmental protection is needed, install the entire assembly within a suitable enclosure.

Compatibility:

  • Compatible with busbar systems designed for this type of switch-disconnector.
  • Utilizes standard ILS labeling systems.
  • Accepts S2C-H6R auxiliary contacts.
  • Suitable for AC voltages between 12V and 400V.

Care:

  • Periodically inspect for dust or debris. Clean with a dry or slightly damp cloth if necessary. Ensure the device is de-energized before cleaning.
  • Check screw tightness during routine maintenance.
  • Do not use abrasive cleaners or solvents.
  • Ensure the enclosure (if used) maintains its integrity to protect the IP10-rated device.