Finder 38 Series Relay Module - 6A - 24V AC

This Finder 38.61.0.024.0060 relay module features a 6A switching capacity and a 24V AC/DC coil vo...

Best current price£14.99from Rapid Online - Rapid Electronics Ltd.

All Offers

15 offers from £14.99 - £37.19

View price history by clicking the chart icon.

Rapid Online - Rapid Electronics Ltd.Finder 38.61.7.024.0050 Relay Module 6A SPDT-CO 24VDC AgNi
Free delivery in 1–3 days
£14.99
Visit shop
Tameson UKFinder 38.61 Interface Relay Module 6A 24Vdc Screwless - 38.61.7.024.0050
Free delivery in 1–3 days
£15.17
Visit shop
eBayFinder Relay Module 6A SPDT-CO 24VDC AgNi
£3.50 delivery
£17.99
Visit shop
Blueperry agriculture (UK)Finder Silver Relay Module 1Co 6A 24Vdc S. 386170240050
Free delivery in 1–3 days
£34.94
Visit shop

Product Information

Full details

This Finder 38.61.0.024.0060 relay module is designed for professionals in industrial automation, HVAC, and building management seeking reliable switching for loads up to 6A. Its key benefit is the versatile 24V AC/DC coil voltage and enhanced contact performance with AgNi and gold plating, ensuring durability and signal integrity. A potential caveat for users is the need for specific DIN rail mounting and screwless terminals, which require careful handling during installation.

All features

Series38 Series
Model Part Number38.61.0.024.0060
BrandFinder

Extended Product Information

FAQs

What is the maximum switching current for this relay?

The maximum switching current for this Finder 38 Series relay module is 6A.

What type of contacts does this relay have?

This relay features Single Pole Double Throw (SPDT) contacts, offering one normally open (NO) and one normally closed (NC) contact configuration.

Can I use this relay with a 12V DC control signal?

No, this specific model (38.61.0.024.0060) is designed for a 24V AC or 24V DC coil voltage. For 12V DC operation, you would need a different model from the 38 Series, such as the 38.61.7.012.0050.

How do I connect wires to the screwless terminals?

Strip the wire to the appropriate length and insert it firmly into the designated slot in the screwless terminal. The internal mechanism will grip the wire. Ensure a solid conductor or a ferrule is used for stranded wire for best results.

What is the operating temperature range?

The module can operate reliably within a wide temperature range of -40°C to +70°C.

Is this relay suitable for high-frequency switching?

Yes, the AgNi and gold-plated contacts are designed for enhanced performance and durability, making it suitable for frequent switching applications within its rated capacity.

What are the physical dimensions of the relay?

The dimensions are approximately 6.2mm in width, 76mm in height, and 93.6mm in depth.

Troubleshooting

Relay does not switch when coil is energized

Verify coil voltage is correct (24V AC/DC) and properly connected. Check if the control signal is actually present and at the correct voltage level. Inspect terminals for secure wire connections.

Contacts are welded or stuck

This can happen if the switched load exceeds the 6A rating or if there is a significant inrush current. The module may need replacement. Ensure the load is within specified limits.

Intermittent switching or poor contact resistance

Check for damaged or corroded contacts. Ensure wires are firmly seated in screwless terminals. Ensure the module is operating within its specified temperature range.

Module does not fit on DIN rail

Confirm you are using a standard 35mm DIN rail. Ensure the module's mounting clip is not obstructed or damaged.

Pros and Cons

Pros

  • High reliability due to gold-plated contacts.
  • Flexible 24V AC/DC coil voltage.
  • Compact DIN rail design for easy integration.
  • Tool-free wiring with screwless terminals.
  • Suitable for demanding environmental conditions (-40°C to +70°C).

Cons

  • Limited to 6A switching capacity; not suitable for high-power loads.
  • Requires DIN rail for mounting.
  • Screwless terminals may require specific wire preparation for secure connections.
  • Only one SPDT contact; for more complex switching, multiple modules or different types are needed.
  • Relatively narrow form factor (6.2mm) might be a constraint in some panel layouts.

Setup, Compatibility & Care

Setup:

  1. Ensure the control voltage matches the module's 24V AC/DC coil rating.
  2. Mount the module securely onto a standard 35mm DIN rail.
  3. Connect the input control signal to the coil terminals (typically marked A1/A2).
  4. Wire the load to be switched across the appropriate SPDT contacts (NO, NC, Common).
  5. Ensure wires are stripped to the correct length for the screwless terminals and insert firmly.

Compatibility:

  • Compatible with standard 35mm DIN rail mounting systems.
  • Designed for use with 24V AC or 24V DC control signals.
  • Suitable for switching loads up to 6A resistive.

Care:

  • Keep the module clean and free from dust and moisture, especially around the terminals.
  • Avoid exposing the module to excessive vibration or shock.
  • Periodically check wiring connections to ensure they remain secure in the screwless terminals.
  • Ensure proper ventilation around the module when installed in an enclosure.

Price History

DatePrice
Visit shop