Festo Air Preparation Unit - G1/4''

Best current price£208.77from Tameson UK
Best offers
Shopping.co.uk recommended and popular offers
Festo Air Preparation Unit G1/4'' 1-12Bar 750L/Min 40Μm - 542296
Visit shop
Best current price£208.77from Tameson UK
Shopping.co.uk recommended and popular offers
Festo Air Preparation Unit G1/4'' 1-12Bar 750L/Min 40Μm - 542296
Visit shop3 offers from £208.77 - £332.64
View price history by clicking the chart icon.
This Festo Air Preparation Unit is designed for industrial and technical pneumatic systems requiring clean and regulated compressed air. Its key benefit is providing a comprehensive 3-in-1 solution (shut-off valve, filter regulator, lubricator) in a compact 40mm width, saving space and simplifying installation. A potential caveat is its standard 40µm filtration, which may require pre-filtering for extremely sensitive applications.
| Model Part Number | MSB4-1/4:C3J1M1-WP |
|---|---|
| Brand | Festo |
The filter regulator removes particulate contaminants from the compressed air and allows you to set and maintain a stable, precise air pressure for your pneumatic devices.
The frequency depends on the humidity of your compressed air. It is recommended to check and empty the bowl daily, or whenever a significant amount of condensate is visible.
Use only approved pneumatic lubricant oils. Refer to the Festo documentation or contact technical support for specific lubricant recommendations suitable for your application and operating conditions.
This unit is designed for technical pneumatic systems. For food-grade applications, specific certifications and product variants are required. Consult Festo's product catalog for food-grade compliant solutions.
The filtration grade is 40 micrometers (µm).
The standard nominal flow rate is 750 liters per minute (l/min).
Turn the knob on top of the filter regulator. Lift the knob to unlock, turn to adjust, and push down to lock at the desired pressure. Ensure the system is under pressure when adjusting.
Check if the shut-off valve is open, ensure the unit is correctly plumbed, and verify the inlet pressure is within the operating range.
Verify the pressure regulator knob is set and locked, check for air leaks in the system, and ensure the filter element is not clogged.
Empty the collection bowl more frequently. Ensure the filter regulator is functioning correctly and consider if the upstream air drying system is adequate.
Check the oil level. Ensure the adjustment screw is set correctly and that there are no blockages in the oil passage.
Inspect and clean or replace the filter element. Ensure the pressure setting is adequate and check for any blockages in the inlet or outlet connections.
Setup:
Compatibility:
Care: